Health Medical Devices Equipment Omron Bmi Blood Pressure Machine Hospital Scale With Height Weight Measuring Equipment
Recommend Products
Contact our sales manager for more information !
Model No.
SK-X60HD
Class
Category Ⅰ Grade B
Body weight measurement
Measuring system
Resistance strain gauge load cell
Configured body weight
Sonka body weight
Range of measurement
500kg
Verified precision
±0.1kg
Height measurement
Measuring system
Ultrosonic probe
Configured body height
Sonka body height
Range of measurement
70.0~200cm
Verified precision
0.1cm
Blood pressure measurement
Model
Raycome, RBP-7000
Display
LCD Digital Display
Measurement Method
Oscillometric method
Measurement Range
Pressure: 0 mmHg to 299 mmHg, Pulse: 40 to 180/min.
Accuracy
Pressure: ±3 mmHg, Pulse: ± 5%
Inflation
Electric pump
Deflation
Automatic pressure release valve
Pressure Detection
Capacitive pressure sensor
Memory
84 Measurements with date and time for each user(A and B)
AC/DC adapter
Input 100-240V 50Hz/60Hz,Output 6V/9.6W
Storage temperature/Humidity/Air Pressure
-20°C to 60°C/10 to 95% RH700 - 1060 hPa
Weight
Approximately 2600 g
Dimensions
Approximately 286 (l) mm * 294 (w) mm * 271 (h) mm
Arm Circumference
22 to 42 cm
Measurement of Fat
Measuring system
Multi-frequency 4- Electrode
Measurement frequency
5kHz/50kHz/250kHz/500kHz
Measurement category
"Body fat, visceral fat, body water, muscle, bone mass, basal metabolism"
Material
Electroplating material
Current for measurement
90μA or below
Range of measurement
75.0~1,500.00Ω (0.1ΩUnit)
Measurement of blood oxygen
Blood oxygen probe
CREATIVE KS-CM01
Sensor
Dual wavelength LED
Wavelength
Visible light( Max):663nm, Invisible Light:890nm
Measurement range
35%~100%
Average output power (Max)
≤2mW
Measurement error
In the range of 70% to 100% < ±2%
Accuracy
In the range of 70% to 100% < ±3%
Pulse rate measurement error
30~250bpm (Monitoring error is ±2bpm or ±%2, whichever is the largest)
Working humidity
5℃~40℃
Relative Humidity
15%~95%(Non-condensing)
Atmospheric pressure
70kpa~106kpa
Power supply mode
Powered by ancillary equipment
Range of measurement
95-99%(±2%normal status,±3% motion or weak perfusion,less than 95% undefined)
Body temperature
Infrared thermometer
Calibeur DT-8836
Accuracy
0.1 ℃
Operating Temperature
10~40℃
Storage temperature
0~50℃
Relative humidity
≤85%
Power supply
DC 9V(6F22:a layer-built battery)
Dimensions
150*75*40mm
Weight
Gross weight: 400g, Net weight: 172g
Measurement range
32.0~42.5℃
Object temperature range
0~100℃
Accuracy
5℃~40℃
Power dissipation
≤120mw
Measurement distance
5-8cm
Auto power off
about 15 seconds
Touch display
Display screen
"21”imported color LCD panel, response speed:6ms, bearing a super height of 1500nits, Visible LCD Screen under sunlight."
Temperature and humidity
Temperature:0--50℃;Humidity:10%--90%(Relative,non-compact)
Resolution rate
800*600 / 32bit true color
Brightness and Contrast
400cd/㎡ ; 5000:1
Average trouble-free time of touch panels
Industrial-grade Resistance Touch Panel,more than 20 thousand hours of trouble-free operation;
Life endurance of touch panel
More than 30 million times of trouble-free operation(Tip R0.8mm)
Data output port
LAN network port
Power voltage
100-240 AC (50Hz/60Hz)
Rated power
(100W)Max.
Temperature of operation/Storage
5℃~45℃(-10℃~+60℃)
Computer
Brand: GIFA industrial control, Intel dual core processorCustomer feedback
Contact our sales manager for more information !