Cable Type:TwinconductorConductor Insulation :Fluoropolymer
Outer Jacket Insulation :PVCCable Diameter:3.2mm to 4.2mmHeating Cable Length: From 16m to 170m
Minimum Bending Radius:25.4mm
Voltage Ratings:110V ~240V.Output Rating (linear) :18.5 watts per meterCold lead for Power Connection: 2-wire 16 AWG plus ground braid;2.5 meterlengthStructure Diagram:Specifications:Order details:OEM:Available
LimitedWarranty:12 years1.Howmuchdoesitcosttorun?
Consideranaverageroomsizeof10m2
.Theheatedareaisapproximately80%,or8m2.
Inthecaseofthe150Wmats,whentheheaterisON,thehourlyconsumptionis150Wtimes8m2,or1200Wattsperhour.
Aproperlyinsulatedroom,controlledbytherecommendedenergyefficientthermostats,willoperateatadutycycleof20%to25%(meaning20%to25%ofthetimetheheaterwillbeON,andtherestofthetimeOFF).
Inthiscircumstancetheaverageelectricityconsumptionforheatingtheroomwillbe240-300Wattsperhour.
Theactualhourlycostdependsonyourlocalelectricityrates.
2.ShouldIuseinsulation?
Westronglyadvisetotheuseofinsulationwheninstallingtheelectricunderfloorheatingsystem.Byusinginsulationyoucanreducewarm-uptimeofthefloorfromoveranhourtoonlyafewminutes.Thiswillprovideyouwithagreaterlevelofcomfortandresultinreductionofelectricitycost.
3.IsitsafetouseinWetareas?
Yes,thecablesareearthed.
4.Howeasyisittoinstall?
Thecableelectricunderfloorheatingmatsareextremelyeasytoinstall.
Undertiles,theinstallersimplylaysthecableelectricunderfloorheatingmatdirectlybetweenthesubfloor/insulationandtiles.ThesameflexibletileadhesiveusedforfixingthetilesisusedforbondingtheInsomaxinsulationontothesubfloor.
Underlaminate/engineeredwoodenfloors/vinyl/carpet,theinstallerlaystheheatingmatsontheappropriateinsulationasnormal.Alayeroflatexbasedselflevelingcompound(8-10mm)isthenlaidontopofthecableheatingmat.Oncedry,thewoodenflooring/vinyl/carpetcanbelaid.
Thelayingoftheinsulationandmatscanbedoneeasilybyanyconsumer.Duetotheweblikemesh,inmostcasesaprimerwillalsonotberequired-onlyalittleamountofducktapeisneededtofixthematsdown.
Aqualifiedelectricianmustcompletetheconnectionbetweentheheatingmatsandtheelectricalcircuit.
5.HowdoIknowwhichsizemattoorder?
Measuretheavailableexposedfloorspaceinyourroom.Itisadvisedthatyoupurchaseasystemwhichallows80-90%coverage.Forexample,ifyourroommeasures15m2,youwouldpurchasethe12.7m2Mat.Ifaroomisofanawkwardshapewithmanyfixturesinthecentreoftheroom,itisadvisedthatyoupurchaseasystemthatallowsapproximately80%coverage.
6.Whatifmyroomislargerthanyourlargestavailablemat?
Severalmatscanbeconnectedinparalleltoajunctionbox.Pleaserememberthatthethermostatsallowamaximumof15amps,thereforethemaximumononecircuitisapproximately23m2.Iftheamperageinoneroomexceeds15amps,theneitheracontactorwillneedtobeinstalledbyyourelectricianoranotherthermostatwillneedtobepurchased.
7.CanIcutthemats?
Youcancutthemeshbutnottheheatingcable.
8.Whatisthethicknessofthecable?
Thecableis4mmthick.
9.CanIlaythematsunderheavyobjects/fixtures?
No-thematscanonlybelocatedintheavailablefreespace.Theremustbesomeformofairgapbetweenanyfurnitureandthefloor,sotheheatmayescape.
10.Doesitprovideaprimaryheatsource?
Inmostcasesinanewbuild/wellinsulatedproperty,thesystemcanprovideprimaryheating.Incaseswherehomeshavesingleglazing,vaultedceilings,poorinsulationlevelsorlessthan80-90%cableheatingmatcoverage,thesystemmayneedasourceofbackup.
11.Whatifmymatisalittletoobigfortheroom?
Wronglyorderedmatscanhappen,incircumstanceswherethematisalittletoobigyoucanremovethemeshandlaythecablesclosertogether.Pleasenotethesmallestgapbetweencablesis5cm.Beawarethatindoingthisyouwillfindthisareawiththecableslaidcloserwillbeslightlywarmercomparedtotherestofthearea.
12.Howsafearethemats?
ThematsaremanufacturedandtestedinfullconformitywithIEC(InternationalElectrotechnicalCommission)GlobalQualityStandards.Thecontinuousfoil-coatedscreeningjacketensures100%guaranteeofelectricalsafetyandabsenceifelectromagneticradiation.
13.Whatisthewarrantyofthissystem?
Theheatingmatscomewitha15yearmanufacturerswarranty.
14.Whetheryouchooseanelectricorwaterunderfloorheatingsystemwilldependontheparticularrequirementsofyourproject?
1)InitialCost
Mostelectricsystemsarelowercosttopurchaseandinstall,simplybecuasetherearelessmaterialsrequiredandinstallationisquicker.
2)RunningCost
Currentlythecostofmainsgasislowerthanelectricitysoawaterunderfloorheatingsystemwillcostlessinenergycosts.
3)Maintenance
Electricsystemsaregenerallymaintenancefree.Watersystemsshouldbecheckedregularily(justayouwouldwithyourboilerandconventionalradiators)becausetherearealotmoremovingparts.
4)FloorHeight
Generallyelectricunderfloorheatingsystemsarealotthinnerthanwatersystems,soifyouhaveanexistingfloorthatyoudon'twanttoremovethenwewouldrecommendusingAnbangUnderfloorHeatingmatorundertilecable.
5)Areatobeheated
Ifyouonlyrequireasmallareatobeheatedthenitcanoftenbesimplierandmorecosteffectivetoinstallanelectricunderfloorheatingsystem.
6)Purposeofheating
Doyouwanttheunderfloorheatingtoprovidetotalheatforaroomorjustawarmfloor.Waterunderfloorheatingsystemsaregenerallyusedfortotalheatsolutions,butelectricunderfloorheatingsystemsareoftenusedfortotalheatorwarmfloorapplications.