Product Description
STC-1000 Aquarium incubator seafood machine temperature controller switch refrigeration heating thermostat STC-1000
Power supply: 110-220vac 10%, 50/60hz (or DC12V/DC24V)
Low range of measurement and control temperature: - 50 ℃ ~ + 110 ℃
Resolution :0.1
Low accuracy: + / - 1 ℃
Relay output contact capacity: heating: 10A/240VAC, refrigeration: 10A/240VCA
Type h sensor: imported NTC sensor, wire length 1 m
Shell material: grey ABS flame retardant plastic shell
P0 cooling and heating mode
Please set high temperature start to C for refrigeration mode
Low temperature start is in heating mode, please set it as H
P1 error setting
In heating mode (H) : when the measured value is less than or equal to the set value -- return difference, start the output heating until the set value stops
Under refrigeration mode (C) : start the output refrigeration until the set value stops when the measured value set value + return difference
P2 maximum setting range: the maximum value at the setting temperature shall not exceed this value
P3 minimum setting range: the minimum value at the time of setting the temperature shall not be lower than this value
P4 temperature correction
When there is a deviation between the measured temperature and the standard temperature, this function can be used for correction. The corrected temperature = the temperature before correction + the correction value
P5 delay start time unit: minutes
When controlling the refrigeration of the compressor equipment, the delay time can be set according to the need. When the controller outputs, the equipment will not start immediately. It needs to start after running the set delay time
P6 high temperature alarm
When the measured value is greater than this value, the screen will display -- -- and sound alarm, and force the output to be disconnected
P7 data lock function
Open the data lock to keep the current setting unchanged. At this time, setting temperature and functions are invalid. If you need to modify, you need to close the data lock function
P8 restore factory Settings
Long press SET to switch to P8, press SET once to SET on, and press Rst to restore factory Settings
You can also press and hold the +- key to restore the factory Settings
Iv. Instructions
Please connect the power supply according to the parameters and the circuit diagram, and connect the refrigeration or heating equipment to the output end
Select heating (enter P0 to select H) or cooling (enter P0 to select C) mode according to the need to enter the internal setting
Setting temperature method: press Set screen once, press up and down to Set the required temperature, and press Rst to confirm return
The OUT indicator light of the panel: flashing indicates refrigeration or heating start delay, and constant light indicates output
Digital tube: display LLL for sensor open circuit; HHH shows that beyond the measuring range the thermostat will force a power cut; Display -- -- alarm for high temperature
Related Products
STC-3028rounding Hygrometer TPM-10 XH-W3001 FY-12
Company Information
We specialize in the production of various electronic components. Our mission is to provide customers with the best service, committed to establishing long-term cooperation with customers, looking forward to working with you.
Our Services
1. Listen carefully to customer requests and provide different types of electronic products to meet customer requirements.
2. Respond to customer requests within 10 minutes of working hours to provide the best price to customers.
3. Patience and customer communication, and strive to meet customer requirements.
4. Quickly create a payment order so customers don't have to wait. Accept convenient payment methods: customers can make payment by alibaba trade assurance, Paypal, Credit Card, Bank Wire Transfer, Western Union, etc.
5. Produce high quality products, test, package and produce 100% qualified products.
6. Select the courier company requested by the customer to deliver quickly
7. The customer receives the product and the order is completed.
FAQ
QuestionAnswerQ1:Why choose Alisi?1.We are Alibaba Assessed Gold Supplier.
2. We have best quality control, Best Service and competitive Price.
3.100% QC inspection Before Shipment.
Q2:Can I get samples?Yes, certainly. We will provide the existing samples for free, Sample fee is refundable when you make an order from us. Q3.What about the lead time?When you complete the payment, we will send it to you within 1-3 days. According to the courier company you choose, you can receive our products in front of your house in the fastest 3-5 days.Q4:What are the certifications do you have?As showed in the section of company information, we have CE, FCC, ROSH certifications. As you can see, our company has a strong competitives and great qualified in our business area. We aim to provide the best quality and services to all global clients.Q5:What is the payment method we can support?You can pay by TT transfer, Western Union and credit card through Paypal, which offers total buyer protection;
Certifications
Packaging & Shipping
Packing
We have a professional packaging team. We will use foam wrap to prevent the product from being squeezed and use a solid carton for the outer packaging, which can effectively protect the safety of the product. The outer layer will be completely sealed with tape and can be effectively waterproof. We will assure you that the product will not be damaged during transportation.
Delivery
We have cooperated with many international express delivery companies, including DHL, FedEx UPS, TNT, EMS, China/HK Post, CDEK, ARAMEX, SF, etc. According to your needs, we can choose the cheapest and fastest delivery for you.
Contact Us