Product Description
MJ-560B4 Drager Portable Anesthesia Machine With Ventilator
Anesthesia Machine
Model
MJ-560B
MJ-560B1
MJ-560B2
MJ-560B3
MJ-560B4
MJ-560B5
Part of Anesthesia Machine
Main body
High-strength engineering plastic rack, light, beautiful and corrosion resistan
Scope of application
adult, child(4 years above)
Gas source
O2:0.28~0.6 MPa
O2, N2O: 0.28~0.6MPa
O2, N2O, Air: 0.28~0.6MPa
Flow meter
O2:
n1.0-10L/min
O2:
0.05-1.0L/min 1.1-10L/min
O2,N2O:
0.05- 10L/min 0.05-10L/min
O2,N2O:
0.05-1.0L/min
1 .1-10L/min
O2,N2O:
0.05-1.0L/min1.1-10L/min
O2,N2O:
0.05-1.0L/min
1.1-10L/min
Air:0. 05-10L/min
O2, N2O linkage and N2O Stopper//
When using nitrous oxide, oxygen concentration>25%. When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
Vaporizer
one
One, high-precision evaporator
One, high-precision evaporator
One, high-precision evaporator
Two, high-precision evaporator
Two,high-precision
evaporator
Part of Ventilator
Display mode/
5.7”
5.7”
10.4” TFT
5.7”
10.4” TFT
mode/
IPPV, SIPPV, SIMV, MANUAL
IPPV,SIPPV,
SIMV, MANUAL
IPPV, SIPPV, SIMV, MANUAL, VCV, PCV
IPPV,SIPPV,SIMV,
MANUAL
IPPV, SIPPV, SIMV, MANUAL, VCV, PCV
function/
PEEP, SIGH, IRV
PEEP, SIGH, IRV
PEEP,SIGH, IRV,
IP, standby
PEEP, SIGH, IRV
PEEP,SIGH, IRV, IP, standby
TV /
50~1500ml
50~1500ml
20~1600 ml
50~1500ml
20~1600 ml
Rate/
2~99 bpm
2~99 bpm
2~99 bpm
2~99 bpm
2~99 bpm
SIMV rate/
2~20 bpm
2~20 bpm
2~20 bpm
2~20 bpm
2~20 bpm
I:E/
2:1~1:8
2:1~1:8
4:1~1:82:1~1:8
4:1~1:8
Inspiratory trigger pressure/
-10~20cmH2O
-10~20cmH2O
-10~20cmH2O
-10~20cmH2O
-10~20cmH2O
PEEP/
2~20cmH2O
2~20cmH2O
2~20cmH2O
2~20cmH2O
2~20cmH2O
Pressure limitation/10~60cmH2O
5~60 cmH2O
10~60cmH2O
5~60 cmH2O
SIGH/
1.5 times the inspiratory time/100bpm
SIGH 1.5 times the inspiratory time (60-120 adjustable)
1.5 times the inspiratory time/100bpm
IGH 1.5 times the inspiratory time (60-120 adjustable)
Inspiratory platform///
0~50%/
0~50%
Pressure control///
3~50 cmH2O/
3~50 cmH2O
Pressure slope///
1~10 gear/
1~10 gear
Power/
AC 220V 50Hz (UPS, Storage battery)
Parameters for ventilation monitoring/
B1, B2, B4: tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow - time waveform, PEEP, inspiratory trigger pressure
B3, B5: tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, inhale tidal volume, inspiratory platform, average pressure, autonomous inspiratory rate, oxygen concentration, battery capacity, flow-volume loop, pressure-volume loop
Mechanical Arms///
YES
YES
YES
End-tidal CO2 monitoring
Optional
Other Products
Company Information
Packaging & Shipping
Contact Us