Product Description
Installation and adjustment
When used surface plate ,you should first installation debugging,then you can use it . No significance work on surface plate if they aren't properly positioned .Surface plate should setup on level off, firm without shock place .pls first put the pad iron down ,then put the surface plate on the pad iron ,removal the wooden case and oil . Measurement with the levelness of the surface plate ,when the surface plate isn't level ,pls adjust the pad iron .( In the process of adjusting attention to safety)
Instructions
When put the surface plate horizontal ,pls clean it with Gasoline. Put the inspecting workpiece on the surface plate lightly . With the instrument to measure, assembling, welding and so on .Note : Avoid strong collision between workpiece and surface plate face .
Detailed Product Description
a. Hardness: HB170-240
b. Material: HT200-300
a. Grade: precision grade0-3
b. Specification: 200*100-8000*3000mm