Product DescriptionMedical hospital equipment 6 parameter patient monitor
Main Features
1. 15 inch high resolution color TFT display, resolution: 1024*7682. One level menu, easy to use3. Parameters including ECG, RESP, SPO2 , NIBP, TEMP, Pulse Rate Maximum 720 hour graphic and tabular trends of all parameters 4. Built-in recorder and battery5. Suitable for adult, pediatric, neonatal and vet use6. 13 type Arrhythmia analysis, Multi-lead ECG Waveforms Display in phase, real time ST segment Analysis, Pacemaker detection, Drug calculation and titration7. SPO2 can test for 0.1% weak8. RA-LL impedance respiration9. OxyCRG Dynamic View, Bed to Bed view and short Trend Coexist Display, nurse call system10. Anti-ESU, anti- defibrillator11. Capture dynamic waveforms12. Touch screen is acceptable13. Standard network interface, can connect to Central monitor system14. Standard Configuration: ECG , Spo2 , PR , NIBP , RR , Temp15. Optional: built-in printer, IBP, ETCO2, touch screen, wireless network, cartECGLead mode; I,II,III,AVR,AVL,AVF,VGain:X0.25,X0.5,X1,X2Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal) Resolution:1 BPMAccuracy:+-1%ST measurement Range:-2.0-+2.0mVAccuracy:+-10%Pacemaker:YesSweep Speed:12.5 mm/s,25mm/s,50mm/sBandwidth:Diagnostic:0.05--130HzMonitor:0.5--40HzSurgery: 1-20Hz
HR and Alarm Range
Adult: 15-300 bpm Neo/Ped: 15-350 bpmAccuracy: 1 bpmCMRRMonitor: >105 dbOperation: 105 dbDiagnosis: >85 dbTemperature Measure Range:0-50CResolution:0.1CAccuracy:+-0.1C
spO2Measure Range:0-100%Resolution:1%Accuracy:2%(70-100%)Pulse Rate:20-250BPMResolution:1BPMAccuracy:+-3BPM
NIBPWork mode:Manual,Automatic,ContinuousUnit:mmHg,KpaMeasure Range:Adult: SYS: 40-270mmHg DIA: 10-210mmHgMEAN:20-230mmHgPediatric SYS:40-200mmHg DIA: 10-150mmHgMEAN:20-165mmHgNeonatal SYS:40-135mmHgDIA:10-100mmHg MEAN:20-110mmHgResolution:1mmHgAccuracy:+-5mmHg
Pulse rateMeasure range: 20-300 BPMAccuracy: ±2 BPMResolution: 1 BPM
IBP
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and alarm rangeART: 0-300 mmHgPA: -6-120 mmHgCVP, RAP, LAP, ICP: -10-40 mmHg
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and alarm rangeART: 0-300 mmHgPA: -6-120 mmHgCVP, RAP, LAP, ICP: -10-40 mmHg
Press sensor
Sensitivity: 5 uV/V/mmHgAccuracy (no sensor); ±2%or1mmHgBand width:Normal mode: DC~40HzSmooth mode: DC~12.5Hz
ETCO2
Measure range: 0% - 13%Resolution: 1 mmHgAccuracy : ±2 mmHg @ < 5.0% CO2 (at ATPS)Respiration: 3 – 150 bpmDepth of anesthesia (optional)EEG sensitivity ±400μV Noise <2μVp-p , <0.4μV RMS,1-250HzCMRR >100DbInput impedance >50MohmSample rate2000 samples/sec.(14 bits equivalent)CSI and update0-100.Filter 6-42Hz,1 sec.updateEMG0-100logarithmic.Filter75-85Hz,1sec.update BS%0-100%.filter 2-42 Hz,1 sec.update
Related ProductsCertificationsWhy Choose usPacking & DeliveryContact us