Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Pulse Oximeter, Fetal Doppler, Patient Monitor, Sphygmomanometer, ECGOwnershipPrivate OwnerTotal EmployeesAbove 1000 PeopleTotal Annual RevenueconfidentialYear Established1996Certifications(3)ISO9001, ISO14001, ISO13485Product Certifications(2)CE, Test Re
Establishment:
1996
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Europe
OEM/ODM Service
Sample Available

Qinhuangdao Contec Medical Systems Co., Ltd.founded in 1992,focuses on researching,manufacturing and exporting of electronic medical equipments. Our manufactory covers an area of 32,000 square, Our pr...

1
    YRS
General Supplier
Supplier Homepage Health & Beauty & Medical Health & Medical General Assay & Diagnostic Apparatuses CONTEC CE MS400 touch screen Multi parameter Patient Simulator

CONTEC CE MS400 touch screen Multi parameter Patient Simulator

Get Latest Price
Min. Order / Reference FOB Price
1 Carton US $250.00/ Carton
Local Area: Qinhuangdao, Hebei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: CONTEC
Place of Origin: Hebei, China
Brand Name: CONTEC
Model Number: MS400

Product Description
ConTEC CE MS400 Multi parameter Patient Simulator with touch screen
MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.



Parameters

ECG
Conventional
All leads have the same voltage with the II-lead as the reference
Amplitude
0.5,1.0,1.5 and 2.0mV
ECG Rate
15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340 and 350 BPM
ECG artifacts
50 and 60 Hz, muscle, baseline and breathing
The elevation of the ST segment
+0.8 to -0.8 mV, the step is 0.1 mV
Arrhythmia
Atrial
Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular
Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
Premature Beat
Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC
Conduction Defects
First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
Respiration
Respiration Rate
0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
Impedance
0.2, 0.5, 1.0 and 3.0 Ω
baseline impedance
500, 1000, 1500, 2000Ω
Apnea
12 s, 22 s, 32 s
Temperature
Four temperature
0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)
Accessories
Standard accessories 9V/1A(CE) power adapter
an User manual
a packaging box
a plastic packaging
Optional accessories a power adapter(15V/1A)(UL)
a power adapter(15V/1A)
a temperature cable
an IBP cable
a CD disk(including a case conversion software)
Four IBP Channels
Channel 2
The default
00/00mmHg
Artery
120/80
Dynamic IBP(unit: mmHg)
Radial
120/80
Left Ventricle
120/00
Right Atrium(CVP)
15/10
Channel 1
Right Ventricle
25/00
Artery
120/80
Pulmonary Artery
25/10
Radial
120/80
Pulmonary Wedge
10/2
Left Ventricle
120/00
Left Atrium
14/4
Channel 3
Channel 4
Artery
120/80
Auto Swan-Ganz (every 15 seconds)
RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Radial
120/80
Man Swan-Ganz
press ENTER key to change every time

Left Ventricle
120/00
Static-Pressure Levels
Right Atrium(CVP)
15/10
Channel 1
0, 80, 160, 240, 320 and 400mmHg
Right Ventricle
25/00
Channel 2
0, 50, 100, 150, 200 and 250mmHg
Pulmonary Artery
25/10
Channel 3
0, 20, 40, 60, 80 and 100mmHg
Pulmonary Wedge
10/2
Channel 4
P4 tracks the static pressure levels of P3
Left Atrium
14/4
Features

1. Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function).
2. Simulate four-channel IBP data.
3. Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data.
4. Simulate four kinds of temperature data.
5. Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
6. Simulate standard ECG calibration, adult and pediatric ECG signal.
7. ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested.
8. Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate.
9. Power supply: rechargeable lithium battery or linear adapter, which reduces interference.
10. Optional operation modes: keys and touch screen.

Our Company
Contec Medical Systems focusing on research,manufacture and distribution of medical instruments,was founded in 1996 as a high-tech company.
CONTEC produces and distributes more than 2000000 products per year, which were distributed to over 200 countries and regions.CONTEC hopes to cooperate with international companies to supply more innovative design and advanced technology products .
We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship .

office

production department
Inspection department

Certifications
Packing & Delivery
FAQ
1.Payment
TT via PayPal, bank transfer,west union,Ali trade assurance.
2.Delivery
Within 7-10 working days after receipt of the payment
3.Shipment
DHL, UPS, EMS, FEDEX,sea shipping, air shipping for your choice
4.Warranty
18 months warranty for main units, and 6 months for accessories.

Send your message to this supplier

*From:
To:
Contec Medical Systems Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now