Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Pulse Oximeter, Fetal Doppler, Patient Monitor, Sphygmomanometer, ECGOwnershipPrivate OwnerTotal EmployeesAbove 1000 PeopleTotal Annual RevenueconfidentialYear Established1996Certifications(3)ISO9001, ISO14001, ISO13485Product Certifications(2)CE, Test Re
Establishment:
1996
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Europe
OEM/ODM Service
Sample Available

Qinhuangdao Contec Medical Systems Co., Ltd.founded in 1992,focuses on researching,manufacturing and exporting of electronic medical equipments. Our manufactory covers an area of 32,000 square, Our pr...

1
    YRS
General Supplier
Supplier Homepage Health & Beauty & Medical Health & Medical Emergency & Clinics Apparatuses CONTEC CMS800F portable optional twins Maternal fetal monitoring medical supplies

CONTEC CMS800F portable optional twins Maternal fetal monitoring medical supplies

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $800.00/ Unit
Local Area: Qinhuangdao, Hebei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: CONTEC
Place of Origin: Hebei, China
Brand Name: CONTEC
Model Number: CMS800F

Product Description
ConTEC CMS800F portable Medical Equipment portable fetal monitor ctg machine
Features:
1.Single or Twins Ultrasound transducer
2. Data Graph and Trend Table Review of both mother and fetal
3. Built-in thermal printer
4. Built-in Network capability for connect with central monitoring software
5. Programmable alarms
6. All the colors and looks or the parameters can be customsized
7. Multi-face views, select focus on mother or fetal
8. Storage of patient information and data Performance Specifications:
9. Display:8.4" Color TFT
10. Resolution:640x480
11. Display Mode:Standard View,Fetal View,Mother View
12. Indicator:Power indicator light, Alarm sound
13. Interface:Socket for connecting fetal's FHR, TOCO, and
Fetal Movement sensorSocket for connecting mother's ECG,
NIBP and SPO2 sensor. Net Socket(RJ45) for communication cable with
Central Monitoring Station Sofrware.
13. Power Supply:AC 100 ~ 240V, 50/60Hz, Powe < 60VA
14. Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 96 hours.
15. Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 items.
16. Alarm:Ajustable High and Low limits. Three level audible and vistual alarm.
17. User Configuration:All the color of parameters and waves can be set according to user's willing.
Specification
Safety
Type of protection against electric shock: Class Ⅰ
Degree of protection against electric shock:
FHR1, FHR2, TOCO, FMOV, NIBP: type BF applied part
ECG, SpO2: type CF applied part
Voltage: AC 100 V~240 V
Frequency: 50/60 Hz
P<60 VA
Fuse: T1.6AL250V
Display
8.0"color LCD display, 60° convertible screen
Display contents: bed No., pregnancy weeks, age, paper speed, time, volume, alarm status, transducer connection status, recorder status, FHR data and curve, contraction data and curve, fetal movement times and mark, ECG data and curve, SpO2 data and curve, NIBP data, etc.
Print
Recording paper: Z-type thermal printing paper
Print width: 112 mm
Valid print width: 104 mm
Paper speed: 1 cm/min, 2 cm/min, 3 cm/min(optional)
Recording contents: hospital name, patient name, case No., bed No., pregnancy weeks, paper speed, date, time, FHR curve, contraction curve, fetal movement mark, etc.
Trend Recall
Short trend: 1h, resolution: 1s, 5s
Long trend: 72h, resolution: 1, 5, 10 minutes
Alarm event recall:
Recall for 71 alarm events of all parameters and 8/16/32 seconds of corresponding waveform.
Arrhythmia alarm event recall:
Recall for 60 alarm events of arrhythmia and 8 seconds of corresponding waveform
NIBP measurement recall:
Recall for the latest 400 NIBP measurement data
Ultrasound probe
Nominal frequency: 1.0 MHz
Work frequency: 1.0 MHz±10%
Negative peak sound pressure : p_<1 MPa
Output beam intensity : Iob<20 mW/cm2
The peak time space peak intensity: Ispta<100 mW/cm2
The average time space peak intensity: Isata<10 mW/cm2
FHR
Range: 50 BPM~240 BPM
Resolution: 1 BPM
Accuracy: ±2 BPM
TOCO
Range: 0~100%
Resolution: 1%
Nonlinear error: ≤±10%
RZ way: manual
Fetal Marking
Manual button
ECG
Lead Mode: 3-lead (I, II, III)
5-lead (I, II, III, aVR, aVL, aVF, V)
Waveform: 3-lead, 1-channel
5-lead, 2-channel
Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV
HR
Measurement and alarm range: 15~300 bpm
Resolution: 1 bpm
Accuracy: ±1% or ±1 bpm, whichever is greater
NIBP
Measurement method: Oscillometry
Mode: manual, automatic, continuous
Measuring interval in automatic mode : 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 min
Measuring period in continuous mode: 5 min
Alarm type: SYS, DIA, MEAN
Measurement and alarm range:
SYS :40 mmHg ~ 270 mmHg
DIA :10 mmHg ~ 215 mmHg
MEAN: 20 mmHg ~ 235 mmHg
Resolution:
Pressure: 1 mmHg
Cuff accuracy: ±3 mmHg
Measurement accuracy:
Maximum mean error: ±5 mmHg
Maximum standard deviation: 8 mmHg
Overpressure protection: 297±3 mmHg
SpO2
Measurement and alarm range: 0~100 %
Resolution: 1 %
Accuracy : 70~100%, ±2 %
0~69%, unspecified
Pulse Rate
Measurement range: 25 BPM~250 BPM
Alarm range: 0 BPM~254 BPM
Resolution: 1 BPM
Accuracy : ±2 bpm or ±2 %, whichever is greaterAccessories
A three-in-one Transducer (Ultrasound TransducerⅠ, TOCO Transducer, Remote Marker)
Integrated adult SpO2 probe
Integrated ECG module
ECG cables
ECG electrodes
Adult cuff
NIBP extension tube
NIBP joint
Abdomen belt
Thermal recording paper
Power cord
Earth line
Fuse
User manual
Company Information