Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Pulse Oximeter, Fetal Doppler, Patient Monitor, Sphygmomanometer, ECGOwnershipPrivate OwnerTotal EmployeesAbove 1000 PeopleTotal Annual RevenueconfidentialYear Established1996Certifications(3)ISO9001, ISO14001, ISO13485Product Certifications(2)CE, Test Re
Establishment:
1996
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Europe
OEM/ODM Service
Sample Available

Qinhuangdao Contec Medical Systems Co., Ltd.founded in 1992,focuses on researching,manufacturing and exporting of electronic medical equipments. Our manufactory covers an area of 32,000 square, Our pr...

1
    YRS
General Supplier
Supplier Homepage Health & Beauty & Medical Health & Medical General Assay & Diagnostic Apparatuses CONTEC ECG600G medico elettrocardiografo ecg portable medico cardiaca ecg ekg machine

CONTEC ECG600G medico elettrocardiografo ecg portable medico cardiaca ecg ekg machine

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $450.00/ Piece
Local Area: Qinhuangdao, Hebei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: CONTEC
Place of Origin: Hebei, China
Brand Name: CONTEC
Model Number: ECG600G

Product Description
ConTEC ECG600G elettrocardiografo 12 lead portable 6 channel ecg machine ekg machines pc
Instructions
ECG600G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.
Function
1)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.

2)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).

3)Full-digital filter design, anti-baseline drift, AC and EMG interference.

4)Adjust the baseline automatically, optimize the print setting and optional rhythm leads.

5)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.

6)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.

7)With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.

8)Sync collection for 12-lead ECG, multiply printing formats, including 2x6+1(rhythm lead), 2x6, 3x4, 3x4+1(rhythm lead), 4x3, 4x3+1(rhythm lead), 6x2, 6x2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc.

9)Display of 3/6/12-lead ECG, "Lead off" and "Lack of paper" on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database.

10)Time print can be set to every 1/2/3/5/10/20/30/60 minutes.

11)Print setting, including “Print and save”(print waveform and save case), “Print no save”(only print waveform but not save case), “Save no print”(only save case but not print waveform).

12)AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time.

13)Store more than 1000 cases, convenient for case review and statistic.

14)Multi-language(Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakstan, Russian and Ukrainian) interface and report.
Performance Input modefloating and defibrillation protectionFrequency response0.05Hz ~ 150Hz(-3dB~+0.4dB)CMRR>60dB, >100dB(add filter)Time constant:≥ 3.2sPatient leak current<10µACalibration voltage 1mVSensitivity2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%Noise level<15µVp-pInput circuit current≤50nAInput impedance≥50MΩSampling accuracy 12-bit
Safety classification: class I, type CF and defibrillation-proof applied partRecording mode thermal printing systemAuto recordset record according to auto record format and mode, automatically switching leads, measuring and analyzing.Rhythm recordset record according to rhythm record format and mode, automatically measuring and analyzing.Manual recordset record according to record format, manually switching leads.Measurement parameters HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)Paper size80mm(W)x20m(L)Power frequency filter AC 50Hz/60Hz(-20dB)Sampling frequency1000HzEMG interference filter 25Hz/35Hz (-3dB)Paper speed
Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%

Accessories
Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual Optional:
ECG-Sync software+USB cable
ECG electrode
Bag
Conductive gel


Physical characteristic
Dimension: 315mm(L) x 215mm(W) x 92mm(H)
Weigh: 1.7Kg
Company Information
BrandCONTEC

Send your message to this supplier

*From:
To:
Contec Medical Systems Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now