CONTEC MS100 SpO2 Simulator Patient Oximeter Simulator

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $400.00/ Unit
Local Area: Qinhuangdao, Hebei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: CONTEC
Place of Origin: Hebei, China
Brand Name: CONTEC
Model Number: MS100

Simulator

Product Description
ConTEC MS100 SpO2 Simulator Patient Oximeter Simulator On sale
Brief Introduction

MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.
Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.
Features
1.Separated connection between simulator probe and host, operation and test are more convenient.
2. 262K color and 320*240 TFT, adjustable brightness level.
3.Film key-press, makes the operation more comfortable.
4. Power with chargeable lithium battery, can display the charge information of battery.
5. Key volume, can open or close.
Main Functions
1. Oxygen saturation simulation;
2. Pulse rate simulation;
3.Patient state simulation preset;
4.Can test the reaction time of device;
5. Can simulate the SpO2 and pulse rate under different amplitude;
6. Can test the performance of device under different interference source;
7. Can select different R-curve.
Main Parameters
SpO2
Measuring range: 35%~100%
Resolution:1%
Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
Pulse rate
Measuring range:25bpm~250bpm
Resolution:5bpm
Error:1%±1bpm
Amplitude
Measuring range:0.000%~20.000%
Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
Patient state
24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
Voltage
DC 3.6V~4.2V
Power Supply
Voltage 3.7 rechargeable lithium battery x 1
Battery working life
Charge and discharge no less than 500 times.
Accessaries
1.A MS100 user manual
2. A 5.0V adaptor