polymerization offset negative type CTP plate, applied using 405nm violet laser diodes as a light source CTP platesetter.
applicableto the newspaper, books andpackaging printing, which is applicable to the resolution of the outputdevice to 100-150lpi 1000-2400dpi plusnetwork files when using 1800-2540dpi equipment 175lpi or higher resolution outputplus net accuracy when a file that can be used for commercial printing. But the need to find appropriate parameters and optimum machine and plate matching when using the machine, otherwise themachine, dot 10% or less have lost points on the plate phenomenon, 30% -70% of the networkhas reduced the phenomenon. Therefore not recommended for high-resolution outputfile.
PlateStructure : protectivelayer/Photosensitive layer /Grained layer/ Aluminum base
Platemakingprocess
Violetlaserscanningpreheatwashing,developing,gluePH-V
Plate sensitivity
70 uj / cm2
Applications
newspapers,books,packaging and commercialcolorprinting
Version of the base thickness
0.15mm-0.30mm
The maximum width
1060mm
PlateColor
green
responserange
405nm
High resolution
2-98%@ 175lpi (after linearization correction)
Pressrun(tenthousand)
15 (not bake), ≥50 (bake)
adaptability
recommendbake, pressrun 100 000pcs
Storageperiod recommend, 16 months
PH-Vversion of the storage period of 12 months under therecommended conditions (temperature <30℃, relative humidity range of 30-60%).
-V recommended safety light environment (YG10 consider threeoverlapping film produced by Encapsulite resulting yellow light)
plate 20-26 ℃, relativehumidity of35-55% is more appropriate, Plate balance in this environment for at least12 hours
pick & place: the entire platemaking process shouldwear thin cotton gloves, open the box to extract the plate should avoid corners or edges ofthe paper plate scratch or rub injury forum
PH-V versionis recommended developing conditions
Developing conditions
PH-V
Developer
PH-P
Replenisher
PH-P-R
Preheating temperature
Warm-up timeThermaxz110-140℃ range
recommended 250-350℃Pre-washed andwatertemperature
watertemperature 30 ℃
Washing brushpressure
300g / cm2,120rpm
Water
500-800ml/ m2
Developing temperaturetemperature
24 ± 1 ℃, timeof 20 ± 4s
developing brushpressure
350g / cm2, 90-130rpm
PH value of the developer control
11.9 ± 0.3
Developing dynamic supplemented
100-120ml/ m2
Staticadditionaldeveloper
developing tank volume≤25L 50ml/ hrAdditionaldeveloper
normal state of life Developing tank volume ≤25L 600m2 Developing tank volume> 25L 1200m2
Insufficient amount, the longest available in two months
The developing cartridge
Reusablefilter accuracy 150umAfter washing
Washing brushpressure 300g / cm2,Drying
60℃
Third,theanalysisoftheuse of commonproblems and solutions
Tohelp usersuseof PH-V photopolymerization CTP correctly, where the light-sensitive version of the user during use common problems, causes and solutionsare summarized included in the table below.