Business Type:
Manufacturer/Factory,Trading Company
Business Range:
dental lab equipment, dental chair, Dental implant, dental handpieces, orthodontic bracket
Establishment:
2016
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
South America, Mid East, Southern Europe
OEM/ODM Service
Sample Available

NOVO EXPORT LIMITED We are NOVO EXPORT LIMITED located in Shenzhen,China .We are specialized processing and production of dental equipment and materials.We have been in dentistry for more than 10 year...

1
    YRS
General Supplier
Supplier Homepage Health & Beauty & Medical Health & Medical Dental Equipment shadowless 5 bulbs dental led handpiece high speed turbine with light

shadowless 5 bulbs dental led handpiece high speed turbine with light

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $61.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: novo
Place of Origin: Guangdong, China
Brand Name: novo
Model Number: HP-LED 58 dental handpiece
more than 320,000 rpm
Working air pressure
0.25--0.3Mpa
Cooling water
5 water sprays
Bur applicable size
1.590-1.600 mm
Head standard
standard /torque
Chuck bur
push button
Bearing
ceramic /stainless bearing
available connection
M4 /B2 / Coupling design
Noise
less than 65 dB
packing
plactic box for unit packing ,10pcs for one carton
Disinfection
autoclavoble to 135 ℃
Brand
NOVO
OEM available
YES
Customized
YES
Advantage:
1. 5 LED lamp,shadowless lighting ensures brightness at all preparation area.
2. 5 points spray, perfect cooling treatment.
3. Anti-skid body and non-scratch design, easy to control and more comfortable.
4. Burs would be easily changed with the push button.
Dental handpieces right use way:
1. The need to use a clean , dry , oil-free air compressors for medical use ;
2. The air pressure between 2.3-2.8kgf / cm2;
3. Place the adapter with quick connector at the bottom of a combination of dental handpieces , and confirm that the card lock fixed ;
4. Press the pedal , handpiece operation and examine whether the normal operation of the spray head . If everything is normal, you can start using the handpiece .
After each patient use , maintenance should be done as follows
1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate ;
2. Use a metal needle to clean the spray holes and fumaroles ;
Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle.
3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes ) ;
4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom ;
5. The handpiece with quick connector combination ( first determine the water switch is turned off )
6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie ) ;
7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain ;
8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization.
Handpiece routine maintenance
Fault: the occurrence of undesirable phenomena water
( 1 ) inadequate water supply .
( 2 ) the amount of water is not uniform.
( 3 ) is not a mist of water .
( 4 ) no water completely .
Solution: Check the water blocked the site
( 1 ) pipeline : the turbines removed to check for the amount of water flowing from the pipeline . If there is no water out, it may be pipes or water treatment units system problems ( bad or wrong operation , there is not enough water pressure ) .
( 2 ) interface : the interface conductors commissioning . Without the right amount of water flowing out , it indicates a problem at the interface ( such as clogged scale water supply systems or interface loose , resulting in insufficient pressure ) .
( 3) The body of the phone : the shaft from the turbine to remove , install interface running on . If there is no outflow amount of water, it is the problem turbines within the body ( water holes or dirt clogging turbines within the water supply system clogging ) .
( 4 ) shaft : If the above three normal outflow of water , it is the axis of the core problem (water nozzle clogging ) .
Axis core spray nozzle clogging .
Solution:
( 1 ) remove the end cap , remove the spool core .
( 2 ) the brush behind the nozzle cleaning needle is removed , insert the needle straight spout .
( 3 ) nozzle cleaning needle to be inserted into the upper section of the trench ( bur through jet slot ) at the till . Part of this special brush with dust brush clean.
( 4 ) the use of three guns and other bur blowing from the side .
(5 ) mounted on the shaft head , be sure to properly install the 0 -ring .
bur easy to fall off , bur not pull it out , the axis vibration.
Solution:
(1 ) Select the bur , bur must confirm the allowable speed range specified by the manufacturer , or else when the cutting load is greater than the chuck clamping force bur easily.
( 2 ) mini- head bur should use a short handle , easy to fall off when attached to the shank burs .
( 3 ) Do not use worn tapered bur , curved bur bur missing edge , otherwise it will affect the durability of the bearing Must be drawn .
(4 ) installation bur bur confirm indeed firmly installed , if not into the depths of shallow plug can cause dangerous bur flying .
Contact
Cathy
Skype
dental-novo
Whatsapp
+86 189 2646 6077
Tel
+86 189 2646 6077

Send your message to this supplier

*From:
To:
Shenzhen Feisi Trading Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now