gas chromatography mass spectrometry machine

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $32000.00/ Set
Local Area: Dongguan, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: HD
Warranty: 1 year
Certification: CE, ISO
Customized support: OEM, ODM

Gas Chromatography Mass Spectrometry Machine
Gas Chromatography Machine is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture (the relative amounts of such components can also be determined). In some situations, GC may help in identifying a compound. In preparative chromatography, GC can be used to prepare pure compounds from a mixture
Gas Chromatography Machine using microcomputer keystrokes, large screen LCD liquid crystal display, display intuitive, easy to operate, is a new generation of domestic gas chromatograph, price excellent, low prices, excellent performance, reliable operation
Application field:
1. Analysis of dissolved gas in transformer oil;
2. Analysis of ethylene oxide in medical devices.
3. Analysis of coke oven gas;
4. Pesticide residue analysis;
Alcohol analysis in blood; 5.
6. Analysis of natural gas and liquefied gas;
7. Indoor environment TVOC analysis;
8. Analysis of liquor components;
9. High purity gas analysis;
10. Detection of solvent residue of packaging materials.
And so on......
Performance characteristics.
The third order process is heating up, which can satisfy the analysis demand of the multi-component of the sample.
1) main control circuit adopts new integrated digital electronic circuit, temperature control precision of 0.01 ℃, the performance is more stable;
2) program heating: 13th order, heating rate 0-50 minutes /min;The incremental 0.1 ℃ / min;
The design of the box is further improved to facilitate the rapid cooling of the instrument.
1) the volume is large, and it is the intelligent rear door opening system, which reduces the stable
balance time of the system after the program rise/cooling system;
2) system of heating furnace temperature range is + 7 ℃ ~ 400 ℃;
3) the user can recalibrate the furnace temperature and set the maximum temperature and temperature balance time of the heating furnace.
The uniqueness and selectivity of the system are enhanced.
1) unique sample entrance design solves the sample discrimination;
2) two sampling systems can be installed at the same time: filled column, capillary diverter/non-shunt injection system (with diaphragm cleaning function);
3) optional automatic/manual gas six - pass injection valve sampler, headspace injector, heat analyser, pyrolysis furnace, methanol converter.
4) double column compensation work can not only solve the program drift caused by heating, but also reduce the influence of background noise, and can get lower minimum detection limit.
The operating interface of the instrument is simple and easy to learn, with complete functions and a more humanized design.
1) the Gas Chromatography Machine adopts large-screen LCD screen, which is intuitive and easy to operate;
2) Gas Chromatography Machinehas the function of starting up self-diagnosis;
3) stopwatch function (convenient flow measurement) and operation timer function;
4) power failure storage protection function;
5) keyboard locking function.
The detection system has good stability, high sensitivity and many kinds of detector.
1) Gas Chromatography Machinewhich can be installed at the same time two kinds of the same or different detector: hydrogen flame ionization detector (FID), the thermal conductivity detector (TCD), electron capture detector (ECD), nitrogen and phosphorus detector (NPD), flame photometric detector (FPD), etc.
2) hydrogen flame ionization detector is easy to be disassembled and installed for easy cleaning or replacement of nozzle;
3) high detection sensitivity of high resistance single column thermal conductivity detector, stable baseline stability (stable in 15 minutes);
4) input signals can be used for logarithmic amplification, reduce interference and improve sensitivity.
Technical indicatorsTemperature control range
Room temperature on + 7 ℃ ~ 400 ℃ (0.1 ℃ increment)
Program heating order number
13
Program heating rate
0.1 ℃ to 50 ℃ / min (0.1 ℃ increment)Detection limit
≤5x10-12g/s(n-hexadecane)
Linear range
≥107
The baseline noise
≤6x10-12A/H
Stable time
≤20minSensitivity
≥10000mV·ml/mg(n-hexadecane)
The baseline noise
≤16μV(hydrogen gas is 99.999)Detection limit
≤6x10-13g/s(P)≤5x10-11g/s(P)(methyl parathion)
The baseline noise
≤2x10-13A/HMax operating temperature
350℃
Detection limit
≤5x10-14g/ml(r-666)
The baseline noise
≤20μVDetection limit
≤1x10-12g/s(N)(azobenzene)
≤5x10-13g/s(N)(Marla sulphur phosphorous)
The baseline noise
≤2x10-13A/H
Company Information
Quality Control
Our Services
Haida Equipment Service:
If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.
onsite Service:
1.Device installation; 2.Equipment Operation Test Technology training;3.Equipment Calibration;4.Daily maintenance and maintenance of equipment
Free technical training for visiting factories
24-hour online contact
Free software upgrades
Free information:
1.Product Instruction;2.Product operation instruction/video;3.Experiment Test (test application, test report)
Device Problem Handling:
1. Social media 24 hours online communication;2. Mail Seamless Docking;3. Video Conferencing;4. Artificial free door-to-door service
FAQ
Why choose us?
1. Considerate Service Different countries plugs, manually change the-voltage from 110V to 220V, insurance indicator.
2.Excellent After sale Service:
12 months warranty. Besides, we can help you to repair your problem controller freely, Free replacement parts, even it's not from our factory's. What you need to do is to send us the controller.We can offer operation video and English operation muanual. We can provide video-con
Please feel FREE to contact us if you have any needs. And welcome to visit our OFFICIAL WEBSITE at:
www.haidatestequipment.com
If you want to know more information...
Please leave a message below and click " ConTACT SUPPLIER "
Thanks for your time and attention!

Send your message to this supplier

*From:
To:
Dongguan Haida Equipment Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now