Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Biological Diagnostic Test Kits Infectious Disease Test, Drug of Abuse Test, Tumor Marker Test, Cardiac Marker Test, Urinalysis Reagent Test
Establishment:
2010
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Africa, Southeast Asia, Eastern Europe
OEM/ODM Service
Sample Available

Nantong Diagnos Biotechnology Co., Ltd., which was established in 2006, is a professional company specialized in researching, developing, manufacturing and distributing advanced medical instruments an...

1
    YRS
General Supplier
Supplier Homepage Packaging, Advertising & Office Other Service Fertility rapid test kit fsh test strip

Fertility rapid test kit fsh test strip

Get Latest Price
Min. Order / Reference FOB Price
1000 Piece US $0.34/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: DIAGNOS
Place of Origin: Jiangsu, China
Brand Name: DIAGNOS
Model Number: FSH Test kit

Our Adantages
Diagnos FSH rapid test kit
DETECTION PRINCIPLE
Diagnos FSH rapid test is a chromatographic immunoassay in-vitro diagnostic test for the qualitative detection.It adopts the principles of double antibody sandwich method to test the FSH in the urine.
SPECIMEN COLLECTION
1. Fresh urine does not require any special handing or pretreatment. Testing should be performed as soon as possible after the specimen collection, preferably during the same day.
2. The specimen may be refrigerated at 2-8°C for 3 days or frozen at -20°C for a longer period of time. Specimens that have been refrigerated must be equilibrated to room temperature prior to testing. Specimens previously frozen must be thawed, equilibrated to room temperature, and mixed thoroughly prior to testing.
TEST PROCEDUREInterpretation of Results:POSITIVE: Two lines are visible and the test line (T) is the same as or darker than the control line (C). A positive result indicates that FSH levels are higher than normal and the subject you may be experiencing peri-menopause. NEGATIVE: Two lines are visible, but the test line (T) is lighter than the control line (C), or there is no test line. A negative result indicates that the subject is probably not experiencing peri-menopause in this cycle. INVALID: Control line (C) fails to appear. Insufficient specimen volume or incorrect test performance are the most likely reasons for an invalid result. Review the procedure and repeat with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor. More Rapid Diagnostic Products Available Including:
Drugs of Abuse, HCV, HBVs,Syphilis,PSA,AFP,Pregnancy, Ovalation(LH),Cardiac Troponin I, TB, Malaria, H.pylori,Saliva alcohol test,urinalysis test.
Related Products

Other Products

Company Information
Packaging & Shipping
FAQ
Q1.What's the method you use to do the test?
A: Colloidal Gold Method.Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream. Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.
Contact Us
Contact Us
Promise:We will offer our good after sale service always!as we strongly believe,QUALITY and SINCERE is very important among countries cooperations!
seline;">Welcome to enquiry .Pls feel free to contact usContact Name:IVY ZHU
E-mail:sale04@diagnosbio. com
WhatsApp/Wechat:+86-13962910709
Mobile:+86-13962910709
Skype:goldenmed-01
Office call:+86-0513-80116067

Send your message to this supplier

*From:
To:
Nantong Diagnos Biotechnology Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now