Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Biological Diagnostic Test Kits Infectious Disease Test, Drug of Abuse Test, Tumor Marker Test, Cardiac Marker Test, Urinalysis Reagent Test
Establishment:
2010
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Africa, Southeast Asia, Eastern Europe
OEM/ODM Service
Sample Available

Nantong Diagnos Biotechnology Co., Ltd., which was established in 2006, is a professional company specialized in researching, developing, manufacturing and distributing advanced medical instruments an...

1
    YRS
General Supplier

Home hospital use LH ovulation test midstream

Get Latest Price
Min. Order / Reference FOB Price
5000 Piece US $0.20/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Diagnos and OEM
Place of Origin: Jiangsu, China
Brand Name: Diagnos and OEM
Model Number: DNSLH02

LH Ovulation reagent strip / cassette / midstream test
The One Step LH Urine Ovulation Test is fast and easy to use. It is a qualitative test that can predict when there is a LH (luteinizing hormone) surge, and in turn, when you are likely to ovulate.
Strip
1. Allow the sealed LH test pouch, urine sample, and control solution to reach room temperature (18-30°C).
2. Remove the LH test strip from the sealed pouch.
3. Immerse the strip into the urine with the arrow end pointing towards the urine. Do not immerse past the MAX (marker line). Take the strip out after 5 seconds and lay the strip flat on a clean, dry, non-absorbent surface (such as the mouth of the urine container).
4. Wait for colored bands to appear. Depending on the concentration of LH in the test specimen, positive results may be observed in as little as 40 seconds. However, to confirm negative results, the complete reaction time of 10 minutes is required. Do not read results after more than 30 minutes.
Cassette
1, The Ovulation test is formulated for use with fresh urine specimens. Wear glove and use urine cup to collect urine
2, Remove the test cassette from its foil pouch. Sample well Test lineControl line
3, Draw urine sample into dropper, and dispense it into the sample well on the cassette (2~3 drops, approximately 100uL). Be careful not to overfill the absorbent pad.
4, Read results within 10 minutes.
5, Discard the test device after single use in the dustbin.
Midstream
1. Remove the midstream from the foil pouch.
2, Remove the cap and place on the other end to expose the absorbent tip.
3 Hold the stick by the thumb grip with the exposed absorbent tip pointing downward. Urinate on the absorbent tip only until it is thoroughly wet.
4, Use the cap cover the absorbent tip,Lay the test stick down on a flat surface with the windows while you wait for the test result.
5, Read the result within 10 minutes.
6, Discard the test device after single use in a dustbin.
Negative: One pink/purple band forms in the control region; no band is found in the test region, or the color of the test band is less intense than that of the control/reference band. The result indicates basal LH level of the tested specimen.
Related Products

Other Products

Company Information
Packaging & Shipping
FAQ
Q1.What's the method you use to do the test?
A: Colloidal Gold Method.Q2: What's ur MOQ ?
A: Always, for strip format, the MOQ is 5000pcs. While for cassette format, MOQ is 2000pcs, same as midstream. Q3: What's ur packing of the tests?
A: If u choose the low cost, we will suggest u the bulk packing to go. Which means 1 test in a single pouch, then 100/40 pouches in a plastic bag, 50 bags in a carton. If u need to sell in pharmacy/chain shop or some countries which have strict requirements about the packing, u can choose to pack in a box, like 100pcs in a box, or even 1 test in a single box.Q4: What's the main differences when comparing products from different suppliers?
A: U can compare the mainly features of the test: Accuracy, Sensitivity, Specificity, and then the Price.Q5: Some tests can be tested with serum/plasma or with whole blood, so what's the difference?
A: Well, if the specimen is whole blood, people will need buffer, lancet and alcohol swab to help the test. If they buy all the accessories, they can test very easily at home. But if the specimen is serum/plasma, it will need centrifuge to separate serum from whole blood first. This way, it's better to use at lab or hospital. And in some words, serum/plasma test will always give a more accurate results.Q6: How can i distinguish a good test kit?
A: U can judge from the 4facts:
1. Technical data: Such as the accuracy, specificity and sensitivity.
2. Pouch sealing: Tight enough. If the foil pouch is not sealed well, the humidity in circustance will destroy the reactivity of antibodies labeled on NC membrane. Shelf life will be shorten down.
3. Flow speed: The shorter the better?? NO!! The reaction of antibodies on NC membrane and antigens in specimen usually requires quite a while to work sufficiently. U can refer to the instruction for more accurate time.
4. Background: Good test usually gives clean background after running. If there are red smears in the reading window, it usually caused by bad colloidal gold technology or bad NC membrane. Sometimes, the defect caused false positive result in practice.
Contact Us
Contact Us
Promise:We will offer our good after sale service always!as we strongly believe,QUALITY and SINCERE is very important among countries cooperations!
seline;">Welcome to enquiry .Pls feel free to contact usContact Name:IVY ZHU
E-mail:sale04@diagnosbio. com
WhatsApp/Wechat:+86-13962910709
Mobile:+86-13962910709
Skype:goldenmed-01
Office call:+86-0513-80116067

Send your message to this supplier

*From:
To:
Nantong Diagnos Biotechnology Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now