Business Type:
Manufacturer/Factory,Trading Company,Distributor/Wholesaler
Business Range:
Traction, Cpm, Tens, Ultrasonic, Muscle Stimulator
Establishment:
1986
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Eastern Europe, Western Europe, Northern Europe
OEM/ODM Service
Sample Available

We Passive Health Solution are Manufacturer and Supplier of Medical Equipment such as Physiotherapy Equipment, Slimming Equipment Beauty Equipment. Our range of products is used for a variety of medi...

1
    YRS
General Supplier
Supplier Homepage Health & Beauty & Medical Health & Medical Physical Therapy Equipments Interferential Therapy Interferential Interferential Therapy Equipments

Interferential Therapy Interferential Interferential Therapy Equipments

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $1100.00/ Pieces
Local Area: India
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Passive Health Solution
Model Number: SH02
Instrument classification: Class III
Product name: Interferential Therapy 29 Program
Product Description
Digital Interferential Therapy Equipments 29 Program
WORKING PRINCIPLES:
In the Interferential therapy, we make use of two medium frequency alternating these medium frequency currents are not identical & may differ in frequency up to 150 Hz. Two oscillator of frequency are generated & are cross wisely applied to the body by means of four electrode pads. [ch1 & ch2] channel with one pair of pads i.e. Two No. Of pads. One oscillator has a fixed frequency of 4000 Hz the other ranged in the freq. Between 3850 Hz. Both oscillators interfere i.e. intersect inside the body resulting in a signal as a carrier & low frequency part (the difference in frequency) for the actual therapy. In simple words define the interferential therapy as when two medium frequency currents i.e. Ch1 & Ch2 intersect with easy leading interference currents to be generated at the place. For example, let us take two medium frequency current in Ch1 = 4000 Hz & in Ch2 = 3850 Hz. These two currents are applied to any part of the body. The point where the current cross each other. The new beat frequency current set up is amplified which modulated i.e. AMF Amplified modulated i.e. AMF amplified modulated medium frequency & the frequency new current is called interferential current which is 150 Hz by varying the constant frequency of the first it is to produce a range of beat frequencies deep in the patients tissue. Thus, it is possible to create any desired rate in the carrier current.
4 POLE MODES :- The maximum AMF is obtained in the intersection of the two applied alternating currents. The electrodes should be applied accurately. The balance controls (Ch2) enables minor adjustment of the effective stimulation of the four pole method enabled selective stimulation of the deeper lying tissue & is highly of shoulders ,knee, neck & lower back. In this mode there has to be strictly all the four pads that is two of Ch.
4 POLE VECTOR METHOD :- In this mode i.e. 4 pole vector is selected, the 30 sec count down starts to set properly in the channel i.e. (Ch1 & Ch2). In the order not to get jerk to the patient during 4 PV as when we increase the intensity we are not able to understand the output current as it is varying continuously. As in the one of Ch1 o/p constant while ch2 is frequency or currents start varying. It automatically scans the full area appled (4 pads) in this mode amplitude varies but frequency stable of one channel & vice versa for other channel.
2 POLE MODES :- In this mode the AMF interferential current is generated inside the unit & supplied to the patient through two electrodes.This Method makes it very easy to localize the area of stimulation because the AMF is present in skin zones. In this mode it is not necessary to use all the four pads i.e. a pair of pads can be applied individually and two different places at a time.
BEAT FREQUENCY AND SCAN MODE. :- Beat frequency is basically different between output frequency of channels. Which can be varied from 0 Hz to 150 Hz maximum by using beat frequency up/down keys on the front , 80-150 & 0-10 they vary automatically beat frequency as per setting.
OPERATING INSTRUCTIONS:Moisten the electrode and fix in the two cable wires for CH-1 & CH-2.Connect the output socket which is set to the four wires in up section of the front panel.Fix the electrodes on the body of the patient on such a position where the output will cross the applied area.When using 2 pole mode both the channel CH-1 & CH-2 can be used individually at two different places.Connect the unit in the main by main-cord.Switch ON the unit.As soon as the unit is ON the digits will appear.Set the treatment time.Select the base and sweep frequency range.Select the sweep pattern.Select the frequency mode to either 2khz or 4khz.Select the treatment mode.Press START key
Finally increase the intensity gently and cautiously so that the patient starts feeling the current and increase the patient tolerancy capacity.

If there is a difference in current in both the channels this can be equalized by the balance control. Channel is provided for this purpose. Usually this difference is caused due to difference in resistance in the body with two currents are passing.
The currents in CH1 and CH2 are independently measured.
INTERFERENTIAL THERAPY UNIT SHOULD NOT BE APPLIED IN THE FOLLOWING CASES :-
TUMORS PERSON WITH CARDIC DISEASES, ANY SUPPURATIVE INFLAMMATIONS, INSIDE THE HEAD, ABDOMEN, AREA OF THE PREGNENT WOMEN, LOWER ABDOMEN AREA OF THE MENSTRUATING WOMEN, CHILDREN UNDER 10 YEARS OF AGE, BLEEDING AT THE SURFACE OR INTERNALLY.
WARRANTY
THE GOODS ARE WARRENTED FOR A PERIOD OF 12MonTHS FROM THE DATE OF INSTALLATION UNDER NORMAL ConDITION OF USE AS PER MANUFACTURER TERMS & CONDITIONS.
NOTE
DURING THE WARRANTY PERIOD THE GOODS WILL BE REPAIRED FREE OF COST BE THE MANUFACTURER AND NO UN-AUTHORIZED PERSON SHOULD BE ALLOWED TO OPEN THE UNIT UNDER ANY CIRCUMSTANCES. OUR WARRANTY VOID IF THE UNIT IS OPENED AND HANDLED FOR REPAIR BY ANY UN-AUTHORIZED PERSON.Specification Product NameDigital Interferential Therapy UnitOperatingVoltage230 volts AC supply 50 HzMedium frequency4 Khz and 2 KhzNo of programs29programsOutput type100%IsolatedOutputTwo separate outputs CH-1 & CH-2Output Current0 to100 MAOutput FrequencyIt can be varied in 0-150 Hz constant mode by using beat-freq.DisplayGreen colour seven segment display.Timer0-99 minutesScan patternsRectangular, Trapezoidal & TraingularTherapy modes4 pole Interferential therapyCompany ProfilePacking & Delivery Package Height
18 cmPackage Width30 cmPackage Length36 cmPackage Weight3.5kg / pcsPackageStandard Export Carton PackingDelivery Time3-45 days after confirming order,detail delivery date should be decided according to production season and order quantity.Why Choose Us?Contact Information Copyright © Passive Health Solution.All Rights Reserved. Product Ranking Service by Opal Infotech

Send your message to this supplier

*From:
To:
PASSIVE HEALTH SOLUTION
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now