Industrial back pressure and condensing steam turbine generator
1. Cogeneration of heat and electric power
2. Suitable for various working conditions and speeds
3. Automatic adjustment of electric power loading and heat loading
4. Run under extraction or pure condensation operating condition
5. DEH or fully hydraulic governing systerm
6. Compact construction
7. Easy and convenient installation
8. Stable and reliable service
9. Suitable to drive a generator or other machinery
Model
Power (MW) Rated/Max
Inlet Flow (t/h)
Inlet Press (Mpa)
Inlet temp (℃)
Extraction press (Mpa)
Extraction Flow rated/max (t/h)
Steam rate Rated (kg/kw.h)
Exhaust pressure (Mpa)
Rated speed (r/min)
C3-2.35/0.490
3.0/6.0
24.5
2.35
390
0.490
15/20
8.17
0.008
8000L/3000R
C3-2.35/0.981
3.0/3.6
27.6
2.35
390
0.981
15/20
9.20
0.008
8000L/3000R
C25-3.43/0.490
25/30
150
3.43
435
0.490
70/100
5.97
0.005
3000R
C25-4.90/0.490
25/30
140
4.90
170
0.490
70/110
5.563
0.005
3000R
C25-8.82/1.27
25/30
155
8.82
535
1.27
80/100
6.23
3.95
3000R
Back pressure steam turbine
1. Cogenerating steam turbine, working as a main mover in a thermal power station and having a broad range of application in various industries.
2. Power up to 30MW, covering various inlet and exhaust conditions
3. Additional fixed bleed points
4. Simple construction, convenient installation, smooth running and high efficiency.
Power (MW)
Inlet press (Mpa)
Inlet temp (℃)
Inlet flow (t/h)
Steam rate(Kg/kw.h)
Exhaust pressure (Mpa)
3
3.43
435
32.1
10.7
0.490
6
2.35
390
63
10.33
0.294
12
4.90
435
120.5
9.76
0.686