Business Type:
-
Establishment:
2018
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Europe
OEM/ODM Service
Sample Available

1
    YRS
General Supplier
Supplier Homepage Health & Beauty & Medical Health & Medical Emergency & Clinics Apparatuses veterinary clinic emergency artificial breathing apparatus hospital oxygen fresh air ventilator mach

veterinary clinic emergency artificial breathing apparatus hospital oxygen fresh air ventilator mach

Get Latest Price
Min. Order / Reference FOB Price
50 MetricTon US $5000.00/ MetricTon
Local Area: France
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: MeCan
Model Number: Ventilator
Place of Origin: United States
Instrument classification: Class I

Features:
The YSAV90B ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. , it provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation. SPECIFICATIONSPhysical specificationsDisplay10.4'' LCD DisplayMode:pneumatically powered and electrically controlled systemTrolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisionsTechnical Specifications:Gas requirement:Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpasafety valve<12.5 kPaRespiratory Rate1 ~ 99 bpmgas concentration output21% ~ 100% adjustableMaximum Minute ventilation≥18L / minmodes of ventilationA/C, SIPPV,IPPV,SIMV,PSIMV,CPAP,PCV,PEEP,SIGN,SPONT, MANUALVentilator compliance≤30 Ml/kPaPEEP:0 ~ 1.0 kPaPtr:-10 ~ 10 hPaIMV frequency:1~20 bpmI/E Ratio:4:1~1:4, Has the inverse ratio ventilationTidal VolumeSetting Range: 50~1500ML Display Range: 0~2000ml ;resolution ratio: 10mlInspiratory Plateau:0~1sMaximum Safety Pressure≤ 6.0kPaSigh:one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting pointPressure limit range:1.0~ 6.0kPaAirway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.1 kPa ~ 6.0 kPa;Upper: 0 ~ 5.0 kPa±0.2 kPaVentilation Volume alarm:≥ 18L/ MINPower Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120sThe airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.Operating conditionsAmbient temperature:10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement:100-120 Vac, 50/60 Hz; Attention: the AC power supply used for the anesthesia machine must be well grounded.Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. StorageAmbient temperature:-15oC ~ +50oCRelative humidity:no higher than 95 %Atmospheric pressure:86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation Moisture protection and rain protection to ensure that product is protected from natural damage.Safty & AlarmGas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm.Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle.Ventilation Volume AlarmLower: 0~12L/Min;Up: 18L/ MinBattery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.Power On Self TestSelf test before working, assure it's working normally. STANDARD CONFIGURATIONSQTYNAME1 setMain unit4 pcsAdult threaded pipe (Silica)1 setChild threaded pipe (single use)1 pcOxygen Tube1 pcY-Pipe2 pcsMask (Silicom)2 pcsLeather Bag2 pcsFuse1 pcPower Line1 pcOxygen pressure reducer4 pcsHoop1 pcBattery1 pcTools Attachment1 setHumidifier1 setEnglish Version User Manual

Send your message to this supplier

*From:
To:
S.A.R.L PHEBE
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now