Industrial Radial Films (X-ray or Gamma ray)
IXQ80:
Brief description:
* IXQ80 is a kind of Industrial radial films; make NDT to the object by using x-ray or gamma ray.
* IXQ80 is an ideal and wide applied with its characteristics as high sensitivity, high contrast, high clarity and utmost meticulous texture;
* According to EN-584-1 standard, IXQ80 accord with C4 category;
* According to ASTM E1815-96 standard, IXQ80 accord with I category
* According to GB/T 19348.1 standard, IXQ80 accord with T2 category
* According to ISO 11699-1 standard, IXQ80 accord with C4 category
Application field:
* IXQ80 can be used to take X-ray image for medium light metal or thin-wall steels /products, under low voltage. If under high voltage, it is suitable to conduct detection for medium light metal or thin-wall steels.
Rivcha IXQ80 is suitable to detect thick-wall and high density steels /products through high-energy Gamma ray.
Application Objects:
*metal, Castings, welding
*Aircraft Industries, Electron component
*Nuclear industry, Piping, Concrete
Film base
is made under stable-size PET base, the thickness is 0.175mm.
Darkroom lighting
IXQ80 should be operated under indirect safelight lamp (wavelength>520nm). and place it at least 75cm distance between the reflecting surface and films, or use LED light (wavelength660nm—590nm)
Developing
l IXQ80 is suitable for both of automatic and manual developing.
l Manual (developing time 5 minutes, temperature 20°C)
Automatic(developing time 120 seconds, temperature 28°C)
* IXQ80 also can be developed by other supplier’s chemicals
Emulsion features
auto-developing developer and fixer, processing time :8 minutes ,temperature:26-30°C,matches with developing soaking time 120 seconds
Exposed films record
Manufacturer guarantees the record time for permanent film as 50 years, but should observe follow term:
* Films should be developed cleanly and with best photographic fixing.
* Films should be stored under the relative humidity condition between 40%--60% and away from harmful gas.
Storage for unexposed films
Unexposed series films should be stored into original light-tight package and in dry place, low temperature as much as possible, keep away from aggressive steam & gas, harmful gas and any other ionizing radiation. The ideal storage temperature should be 5°C--24°C, Air humidity 40%--60%. Dispose the exposed film as soon as possible.
Steels exposing chart
Condition : Optical density: D=2, front-back lead & platinum screen:0.025mm, FOMA developer & fixer, temperature: 20°C, time: 5 minutes.