Business Type:
Trading Company
Business Range:
Alcohol Tester, Pedometer
Establishment:
2003
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
South Asia, Southern Europe, Northern Europe
OEM/ODM Service
Sample Available

With our first factory founded in Shenzhen in 1996, a second was established there in 1998, and a branch office set up in Hong Kong in 2001. Engaged in the manufacturing of various types of solar prod...

1
    YRS
General Supplier

key ring alcohol tester breathalyser

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $8.50/ Pieces
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: greattop
Model Number: AT 818
color: black
mouthpiece: 5pcs

key ring alcohol tester/breathalyser
PrefaceGeneral Introduction
GT-ALT-11 breath alcohol tester is kind of tester designed to measure concentration result of the breathed alcohol in the human body. This device adopts advanced NM Hot-wire alcohol sensor which has excellent sensitivity and reproducibility, fashion and portable design make it more convenient for personal use. When the alcohol content exceeds the preset limited level, this device would send an audio and video warning to remind your safety.
Main Feature:
Advanced NM Hot-wire alcohol sensor
Quick response
SMD assembling, stable performance
Smart MCU control
Direct testing process LCD indication
Digital LCD display with light blue backup
Portable and fashion design
Audio warning beyond pre-set limit
Sensor Fault Self checking
Battery saved design, low voltage indication
Working Voltage: DC4.5V(3xAAA)Batteries; Working Current: ≤120mA
Working Environment: Temperature -10℃~50℃ Relative Humidity ≤95% No Dews
Display: 3 digitals LCD display with blue backlight
Dimension: 103x65x27mm (LxWxH), ≤64 g Battery excluded
Battery expectancy time: ≥200Times
1. Structure and Function Guide
1.1 Structure Guidepicture: 1Mouthpiece2Buzzer hole3Switch Button4Input for external power5LCD Screen6Vent hole
1.2. Function Guide
2. Operation Instruction
2.1. Slide down the battery compartment on the back side, insert 3pcs AAA 1.5V batteries inside according to battery polarity indication and close it.
2.2. Press the power button for 1S, after 1 beep sound, “ warm up “ will be displayed on LCD , after 20 second with 1 “beep“ sound, “ blow” will be displayed on LCD and start to countdown and inform for testing.
2.3. Blow directly to the mouthpiece, after 4 seconds with 1 ”beep” sound to inform to stop blowing and the test result will be displayed on LCD.
2.4. Unit switch: On test result mode, press “power“ button to change the unit (% BAC-‰BAC -mg/l) the final unit will be displayed for next test.
2.5. Auto Power off: tester will auto power off after test result show on LCD for 20 Seconds.
2.6. The LCD flickering indicates low power of batteries, please replace two “AAA” alkaline batteries
2.7. Sensor fault self checking : when turn on , tester will check sensor’s mode is normal or abnormal, if some abnormal thing is found which can auto repair ( about 10 seconds), if can not be repaired, LCD will display “ ER”.
2.8. If a new testing needed, press the switch button again and repeat the above step 4.2~
3. Notification
3.1. Avoid any fall or strong shock.
3.2. If noise gas with high concentration existed, may the tester won’t work normally.
3.3. If testing is done under low voltage, certain error will be existed between the real value.
3.4. To ensure the testing result, please wait 10 min to take the testing after your drinking.
3.5. Please operate it strictly according to this instruction. If long time not use, when you first begin a new testing, the first two times testing result may be unreliable, just begin testing from the third time, otherwise the result will also not be accurate.
3.6. Do not keep the tester in the environment of Corrosive gas (Chlorine etc) for use or deposit, also in other bad surroundings.
3.7. Under normal detections, sensor life could be more than two years.
3.8. After Long time use, there may be dirt on the tester, please use clean cloth to wipe off. Do not use any hard object or the solvent with any Corrosive ingredient.
Remarks: Common Fault and Solving solutions
Fault
Possible reason
Solution
NO display on LCD
Incorrect battery installation
Insert battery correctly according to polarity
Low battery seriously
New battery replacement
Circuit fault
Contact distributor
No response tonot complete Warm-up
Waiting complete Warm-up
Circuit fault
Contact distributor
FFF display then power off
Sensor fault
Contact distributor
Low voltage display then power off
Low battery seriously
New battery replacement
To keep the continuous improvement of the products, we reserve the right to improve design without prior notice.
The table of comparison for Alcohol in Blood between the mg/L and BAC
The level of Alcohol display in BAC 0.00%
The level of Alcohol display in mg/L
0.01
0.05
0.02
0.10
0.04
0.20
0.05
0.25
0.06
0.30
0.08
0.40
0.11
0.55
0.12
0.60
0.14
0.70
0.16
0.80
0.18
0.90
0.20
1.00
Product Description
Advanced NM Hot-wire alcohol sensor
Quick response
SMD assembling, stable performance
Smart MCU control
Direct testing process LCD indication
Digital LCD display with light blue backup
Portable and fashion design
Audio warning beyond pre-set limit
Sensor Fault Self checking
Battery saved design, low voltage indication
Packaging & Shipping
gift box
Our Services
The quality guarantee period of 1 years
Company Information
Our company was established 15 years ago ,we have been the gold member supplier of alibaba for 13 years ,we have many distributors from all over the world and won a high reputation from them . Look forward to cooperating with more distributors .
FAQ
1.When after drinking, it is recommended to last after 20 minutes
2.If there is no display replace the battery and try again
3.After the result be display for about 10 seconds
4.must blow into the breath inhaler within 10 seconds in testing mode

Send your message to this supplier

*From:
To:
Greattop Electronic Company Limitd
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now

Contact Supplier

Ms. Grace Liu
Sales Department
Sales Manager