Features
• The module have MICRO USB and serial port , so they can communicate with PC and other device c onveniently .
• The normal working voltage for modules is 5V. And module of ICSE014A have a p ower interface of 5V. Parameters are as follows:
ICSE012A
ICSE013A
ICSE014A
U nit
R emark
CC
4
2
8
channel count of module
I
400
250
700
mA
w orking current
U
5
5
5
V
i nput voltage
√
√
√
whether have serial port
9600
9600
9600
bit/s
baud rate of serial port
F
1000
1000
1000
Hz
Module control frequency
&mes;
&mes;
√
W hether have power interface
Interface
Modules all have Micro USB and serial port . Read following for details :
• Micro USB:andard micro USB mother mouth .
• TX : Transmit
• RX : Receive
• 5V : Volt c urrent c ondenser
• GND : Ground
• Power Interface : only ICSE014A have . Interface is used when Micro USB cannot give enough power.
Usage method
1.USB usage method
Module cont with PC through USB . The conon method is as follows:
Then open ” Relay Board Manager ” to operate the module . Read ”RelayBoardManager_Reference” for details of the software.
2. Serial port usage method
Module can communicate with other device directly through serial port .
Module can receive single byte from upper monitor ( baud rate 9600) :
Upper Monitor 0x50 0x51
ICSE012A 0xAB
ICSE013A 0xAD
ICSE014A 0xAC
Module will turn to normal work ate after receive “ 0x51 ” . Then every data byte will control the relay directly . Each bit controls a realy ( ‘ 0 ' mark art , ‘ 1 ' mark op ) . Read following for details:
B it
ICSE012A
ICSE013A
ICSE014A
Remark
0
√
√
√
C ontrol the relay K1
1
√
√
√
C ontrol the relay K2
2
√
&mes;
√
C ontrol the relay K3
3
√
&mes;
√
C ontrol the relay K4
4
&mes;
&mes;
√
C ontrol the relay K5
5
&mes;
&mes;
√
C ontrol the relay K6
6
&mes;
&mes;
√
C ontrol the relay K7
7
&mes;
&mes;
√
C ontrol the relay K8