Models 160 and 160A are the same product
Technical data Type:160A PropertySpecificationStandardNominal x-ray tube voltage160KVIEC60613-2010Operating tube voltage50-160KV Max tube current 2mA Max anode input power320W Max filament current3.7A Filament voltage3.5±0.2V Focal spot size0.8mmEN12543-1999Inherent filtration0.8/mm Be,1.5-2.0mm glass Target materialTungsten Axial maximum radiation
angle60°
IEC/TR 60788-2004Radial maximum adiation
angle80°Cooling methodOil immersed(70℃ Max)and Convection oil cooling Weight1100g LimitsOperation LimitsTransport and Storage
Limits
Ambient temperatureFrom 10°C to 70°CFrom -40°C to 70°C
Relative humidity/From 10% to 90%
Barometric pressureFrom 70kPa to 106kPaFrom 50kPa to 106kPa
We offer customized x ray tube as customer request