Business Type:
Trading Company
Business Range:
Urine Analyzer, Urine Strips, Urine test strips, Urine reader, Fecal Occult Blood Test Kit
Establishment:
2006
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Domestic Market, Mid East, Southeast Asia
OEM/ODM Service
Sample Available

Beijing Huashengyuan Medical Tech.Co. Ltd.is the special enterprise producing series of medical testing instruments and testing reagent strips with 5 million RMB registered capital since established i...

1
    YRS
General Supplier

14 parameters urine test strip

Get Latest Price
Min. Order / Reference FOB Price
300 Barrel US $3.00/ Barrel
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: HUASHENGYUAN
Place of Origin: Beijing, China
Brand Name: HUASHENGYUAN
Model Number: T-14

Product Description
Multi purpurse urine test strip analyser

ISO9001 and CHINA FDA Waived
Easy-to-use urinalysis strips: Dip and read - no additional instruments needed!
Rapid results: Takes from 30 seconds to 2 minutes for results
High quality color chart providing consistent, dependable readings
Cost Effective: 100 strips per canister, at a great priceTechnical Specifications
Analyzer and visual analysis and sensitivity range for Multi purpurse urine test strip

Items
Sensitivity
Analyzer Range
Visual Range
Leukocytes (ca cells/µL)
5-15
Neg.-500
Nitrite (µmol/L)
13-22
Neg.-Pos
Urobilinogen (µmol/L)
3.2-16
3.4-135
Protein (g/L)
0.15-0.3
Neg.-3.0
Neg.-20.0
pH
5.0-9.0
5.0-8.5
Blood(ca cells/µL)
5-15
Neg.-200
Specific Gravity
1.005-1.030
1.000-1.030
Ascorbic Acid (mmol/L)
0.5-0.6
0-5.0
0-6.0
Ketone (mmol/L)
0.5-1.0
Neg.-7.8
Neg.-16
Bilirubin (µmol/L)
8.6-17
Neg.-100
Glucose (mmol/L)
2.8-5.5
Neg.-55
Neg.-55
Microalbumin(mmol/L)
0.10-0.15
Neg.->0.15
Neg.-0.15
Ingredients (based on dry weight at time of impregnation) Instructions
Collect a fresh urine sample in a clean, dry container preferably glass. First morning samples contain the highest concentration of target markers.
Remove one reagent strip from the bottle and immediately replace the container cap, minimizing the exposure of the remaining test strips to light and air.
Completely immerse the reagent pads of the strip in the urine sample and then remove immediately to avoid dissolving out the reagent pads. A red line will appear next to the Control (C) region when the wick has absorbed sufficient urine
While removing the reagent strip, run the edge of the strip against the rim of the specimen container to remove excess urine. Hold the strip in a horizontal position to prevent possible cross contamination of chemicals located in adjacent reagent pads. Place the cap back on and set the device on a flat level surface
Compare the color change of reagent pads to the corresponding color chart on the bottle label. Read results according to the chart's time frame for each panel tested. Read results in 10 minutes. Results not valid if read after 1 hour
Discuss with your physician or healthcare provider and then discard the used reagent strip.
Note: All reagent areas may be read between 1-2minutes for screening positive urine from negative urine. Changes in color after 2 minutes are of no diagnostic value. Please read the result of analysis according to the given time which is noted on the color chart of the bottle.
Results:
Each container of urinalysis reagent strips includes a color coded chart. The reactive color of each panel on the test strip is compared to the closest corresponding color on the result chart. The concentration level range for each chemical marker is indicated below each color block on the result chart. As with all tests dealing with color intensity or color matching, it is often recommended to obtain another person's interpretation of the test result.
Qualifications &Certificates
Warnings
HuaShengYuan Multi purpurse urine test strip are for in vitro diagnostic use.
1) Keep your fingers or other objects from touching the reagent area before testing.
2) Do not use product (opened or unopened) after expiration date. Use of strips beyond the expiration date may yield low results.
3) Store at room temperatures between 59°-86° F. Do not store the bottle in direct sunlight. Use only if tamper evident seals on this carton are intact.
4) Replace cap immediately and tightly.
5) Do not remove desiccant from bottle.
6) Read enclosed directions carefully.
Reagent Strips are for in vitro diagnostic use. They have been determined to be nonhazardous under the guidelines issued by user manual instruction As with all laboratory tests, definitive diagnostic or therapeutic decisions should not be based on any single result or method. The results should never be used as the sole basis for adjusting insulin dosage.
Company information
HuaShengYuanMulti purpurse urine test strip manufacturing system provides a highly reliable product on time. Our test strips are top quality 100% ISO9001-13485 and CE approved 10-14 parameter urinalysis reagent test strips. Through extensive research and development efforts and perfect quality control system from manufacturing, these urine test strips easily and quickly ready for shipment.
Also we are able to provide assorted urinalysis instruments which can be bound with corresponding strips together to use.
Customers’ satisfaction is our working mission and tries to provide more continuous cares with our customers to reach utmost satisfaction, devote ourselves to play an exemplary role in national healthcare services in the future.

Send your message to this supplier

*From:
To:
Beijing Hua Sheng Yuan Medical Technology Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now