Business Type:
Trading Company
Business Range:
Pregnancy test, HCG test, HCG pregnancy test, DOA test, LH test
Establishment:
2007
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Mid East, Southeast Asia
OEM/ODM Service
Sample Available

H.Y.T Medical (Beijing) Co., Ltd. is a professional medical company dealing with all kinds of medical equipment and devices. Our main product line is diagnostic test, including pregnancy test, ovulati...

1
    YRS
General Supplier

Dengue NS1 Antigen and IgG IgM combo rapid test kit

Get Latest Price
Min. Order / Reference FOB Price
5000 Piece US $2.00/ Piece
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: HYT
Place of Origin: Beijing, China
Brand Name: HYT
Model Number: HYT1902011

Dengue NS1 Antigen and IgG/IgM combo rapid test kit
Product Description
Intended Use
The Dengue NS1 Ag-IgG/IgM Combo Test is a rapid chromatographic immunoassay for the qualitative detection of antibodies (IgG and IgM) and dengue virus NS1 antigen to dengue virus in Whole Blood
/Serum / Plasma to aid in the diagnosis of Dengue viral infection. SummaryDengue is transmitted by the bite of an Aedes mosquito infected with any one of the four dengue viruses. It occurs in tropical and sub-tropical areas of the world. Symptoms appear 3—14 days after the infective bite. Dengue fever is a febrile illness that affects infants, young children and adults. Dengue haemorrhagic fever (fever, abdominal pain, vomiting, bleeding) is a potentially lethal complication, affecting mainly children. Early clinical diagnosis and careful clinical management by experienced physicians and nurses increase survival of patients. Dengue NS1 Ag-IgG/IgM Combo Test is a simple, visual qualitative test that detects dengue virus antibodies and dengue virus NS1 antigen in human Whole Blood/serum/plasma. The test is based on immunochromatography and can give a result within 15 minutes. PrincipleThe Dengue NS1 Ag-IgG/IgM Combo Test is a qualitative membrane strip based immunoassay for the detection of dengue virus antibodies (IgG and IgM) and dengue virus NS1 antigen in Whole Blood /Serum / Plasma.
For IgG/IgM Test :The test device consists of: 1) a burgundy colored conjugate pad containing dengue recombinant envelope antigens conjugated with Colloid gold (dengue conjugates), 2) a nitrocellulose membrane strip containing two test lines (T1 and T2 lines) and a control line (C line). The T1 line is pre-coated with the antibody for the detection of IgM anti-dengue, T2 line is coated with antibody for the detection of IgG anti-dengue. When an adequate volume of test specimen is dispensed into the sample well of the test cassette, the specimen migrates by capillary action across the cassette. IgG anti-dengue, if present in the specimen, will bind to the dengue conjugates. The immunocomplex is then captured by the reagent pre-coated on the T2 band, forming a burgundy colored T2 line, indicating a dengue IgG positive test result and suggesting a recent or repeat infection. IgM anti-dengue if present in the specimen will bind to the dengue conjugates. The immunocomplex is then captured by the reagent coated on the T1 line, forming a burgundy colored T1 line, indicating a dengue IgM positive test result and suggesting a fresh infection. Absence of any T lines (T1 and T2) suggests a negative result.
For NS1 Test: In this test procedure, anti-Dengue NS1 antibody is immobilized in the test line region of the cassette. After a Whole Blood /Serum / Plasma specimen is placed in the specimen well, it reacts with anti-Dengue NS1 antibody coated particles that have been applied to the specimen pad. This mixture migrates chromatographically along the length of the test strip and interacts with the immobilized anti-Dengue NS1 antibody. If the specimen contains dengue virus NS1 antigen, a colored line will appear in the test line region indicating a positive result. If the specimen does not contain dengue virus NS1 antigen, a colored line will not appear in this region indicating a negative result.
To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred. Storage and Stability· Store as packaged in the sealed pouch at room temperature or refrigerated (4-30℃ or 40-86℉). The test device is stable through the expiration date printed on the sealed pouch.· The test must remain in the sealed pouch until use. Additional Special Equipment Materials Provided:Test devices,Disposable specimen droppers,Buffer,Package insertMaterials Required But Not Provided
Ÿ Timer Ÿ Centrifuge
Ÿ Specimen collection containers Precautions
· For professional in vitro diagnostic use only. Do not use after expiration date.
· Do not eat, drink or smoke in the area where the specimens and kits are handled.
· Handle all specimens as if they contain infectious agents.
· Observe established precautions against microbiological hazards throughout all procedures and follow the standard procedures for proper disposal of specimens.
· Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.
· Follow standard biosafety guidelines for handling and disposal of potential infective material.
· Humidity and temperature can adversely affect results. Specimen Collection and Preparation
1. The Dengue NS1 Ag-IgG/IgM Combo Test can be performed used on Whole Blood /Serum / Plasma.
2. To collect whole blood, serum or plasma specimens following regular clinical laboratory procedures.
3. Testing should be performed immediately after specimen collection. Do not leave the specimens at room temperature for prolonged periods. For long term storage, specimens should be kept below -20℃. Whole blood should be stored at 2-8℃ if the test is to be run within 2 days of collection. Do not freeze whole blood specimens.
4. Bring specimens to room temperature prior to testing. Frozen specimens must be completely thawed and mixed well prior to testing. Specimens should not be frozen and thawed repeatedly. Test Procedure
Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.Notes:
Applying sufficient amount of specimen is essential for a valid test result. If migration (the wetting of membrane) is not observed in the test window after one minute, add one more drop of buffer or specimen to the specimen well. Interpretation of ResultsPositive:Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.
Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor. Limitations
Contact us
CONTACT: VayneTEL: +86-10-80598795
Wechat / Whatsapp: +86 15859295062EMAIL: vayne(@)hytmedical.com.cnWEB: www.hytmedical.com.cn

Send your message to this supplier

*From:
To:
H.Y.T Medical (Beijing) Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now