HDRB isolators fulfil the following requirements:
Transmit the vertical loads due to permanent and accidental effects;
Capacity to support horizontal loads due to service load conditions with very low displacements
Capacity of isolate the structure by shifting the fundamental vibration period to an optimal and safe level
Capacity to dissipate energy to reduce the horizontal displacement of the isolated structure with respect to the ground
HDRB isolators have the following advantages:
- No damage to the structure that remains due to the elastic response for high intensity earthquakes with no interruption of the structural function. This is a primary goal for strategic structures (hospitals, control rooms, ecc…)
- Very well known and used in many applications both for buildings and bridges
- Very simple maintenance mainly limited to a periodic visual inspection for all the design life
- Capacity to reduce the seismic energy from the ground to the structure with consequent simplification of the structure design
BELOW IS OURHDR TESTING data:Mechanics Performance Testing Results Form 1 Basic Performance (γ=+/-100%)
Test Name
Test Date
Surface
Temperature
(°C)
Surface
Presure
(MPa)
Kv(KN/mm)
Kh(Kn/mm)
Heq(%)
Measured Volue
Measured Value
Measured Value
HDR400*400-2011-17
20110108
24
12
567.2
1.321
14.158
HDR400*400-2011-17
20110408
24
6
1.276
12.066
Mechanics Performance Testing Results Form 2 Basic Performance (γ=+/-175%)
Test Name
Test Date
Surface
Temperature
(°C)
Surface
Presure
(MPa)
Kh(Kn/mm)
Heq(%)
Measured Value
Measured Value
HDR400*400-2011-17
20110108
24
12
1.486
11.609
HDR400*400-2011-17
20110408
24
6
1.280
10.382
Mechanics Performance Testing Results Form 1 Basic Performance (γ=+/-250%)
Test Name
Test Date
Surface
Temperature
(°C)
Surface
Presure
(MPa)
Kh(Kn/mm)
Heq(%)
Measured Value
Measured Value
HDR400*400-2011-17
20110108
24
12
1.515
10.476
Earthquake Engineering Research &Test Center (EERTC) of Guangzhou University
Guangdong Provincial Key Laboratory of Earthquake Engineering & Advanced Technology
(source material)
1.Earthquake Engineering Research &Test Center (EERTC) of Guangzhou University
2.Guangdong Provincial Key Laboratory of Earthquake Engineering Advanced Technology
(EERTC IS China's MOST ADVANCED TECHNOLOGY IN EARTHQUAKE ENGINEERING)We can supply many different kinds of size HDR ,range from 20*20 to 1400*1400.