Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Fire and security detection (Fire alarm panel, Smoke detector/Alarm, Heatdetector, Addressable fire detectors, Flame detector, Combustible gas andcarbon monoxide detector, Reed sensor, Door window contact transmitter, Z-wave sensors) (All for export)Owner
Establishment:
2005
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
North America, Europe
OEM/ODM Service
Sample Available

Welcome to ISC West 2016 show in Las Vegas Booth No. 40127/40129Established in July of 2001, Sentek Electronics Co., Ltd. is a joint-venture enterprise, which locates in Ningbo, a scenic seaport and i...

1
    YRS
General Supplier
Supplier Homepage Electronics Security & Protection Firefighting Supplies 2 Loops Addressable Fire alarm System Fire Alarm Control panel

2 Loops Addressable Fire alarm System Fire Alarm Control panel

Get Latest Price
Min. Order / Reference FOB Price
10 Set US $500.00/ Set
Local Area: Ningbo, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Sentek
Model Number: JB-TBL-8600
Product name: 2 Loops Addressable Fire alarm System Fire Alarm Control panel
Main power supply: AC220V± 15%, 50HZ.

2 Loops Addressable Fire alarm System Fire Alarm Control panel
Sentek JB-TBL-8600 fire alarm control unit and fir e detectors and modules constitute an automatic monitoring and control system tomonitor the fire smoke situation on the site, it uses intelligent algorithms to judge its status (fire alarm or fault or feedback) and accomplish automatic fire alarm and logic function. The control unit uses bus communication to set alarm, monitor and control on the same loop bus. The hardware circuit is controlled by a single chip microcomputer. The layout is simple and compact, and it is easy to install and expand. The control unit is wall-mounted, full English and Chinese LCDMain power supply: display with beautiful appearance, it is a high performance, high-reliability and intelligent fire alarm control unit.Product Description
Specification: Product Name:2 Loops Addressable Fire alarm System Fire Alarm Control panelMain power supply:AC220V± 15%, 50HZ.Battery power supply:DC 24V (2 sealed batteries: 2*12V*4Ah)Product capacity:2 loops*254 points = 508 pointsLoop capacity:Up to 254 points in any combination of 2-wire
smart smoke detector, heat detector, call point, input module,output module and sounder.Direct output:6 groups of wet contacts relay output.Contacts capacity :1A/24VDC, output current 500mA.Battery power output:1 group 24V power output Outputcapacity:1A/24V.Operating Environment:Temperature -10°C~+50°CHumidity ≤95%.Dimensions:450mmx370mmx120mm.Product standard:GB4717-2005, GB16806-200.
2 Loops Addressable Fire alarm System Fire Alarm Control panel
Appearance and dimensions:
System composition ChassisFunction module8600.1 master board (with LCD)
8600.2 power board
8600.4 Master and Bus Control Keypads
8600.5 direct linkage control panel
8600.6 loop board
8600.7 linkage output boardMicro printerPower supply:24V switching power supply 100W, Battery2*12V*4Ah
Main functions:
1 System self-test
The system will test indicator light,LCD screen,sound and so on.
2 Inquiry function
You can see the device type, zone number, definition about whether there are devices, position information corresponding to each address in the loop.
3 Event record
Under this menu, you can see the fire alarm information and other operation record.
4 Data sampling
Data sampling can sample the products in the loop, and displayed as data. The data can be used to judge the status of the products.
5 Setting function
In this function, you can set the password, time and the printer.6 Installation and program functions
(1) Address coding: the control unit can read or write the product address.
(2)Login: Connecting the products to the control unit. Auto login can login the address and type of the products.
(3)Logic programming: Set the logical relationship between the product and the control unit. Including system linkage, bus linkage and direct linkage.
7 Feedback function
The control unit will display the feedback information after start the equipment manually or automatically and send the alarm sound, lights up the feedback light. Feedback is real information about the starting of fire-fighting equipment.
8 Faulty alarm function
The control unit can automatically check the working status of main power supply,battery power supply detectors and modules. If the control unit found any abnormal address during the inspection process, after many /confirm/iations, it immediately reported the fault information of the control unit number, loop number, and address number. The “faulty” indicator light is on, and you can hear the faulty sound. Press the "mute" key to mute.
Related Product
Company Information

Send your message to this supplier

*From:
To:
Ningbo Sentek Electronics Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now