Product Description
S23A Visible Spectrophotometer(Cuvette or Tube)
Feature:
1.The instrument has variable wavelength and four scales: transmittance absorbency concentration and factor.
2.Using universal test tubes or cuvette to make measure directly.
3.The instrument is micro computerized and easy in operation.
4.The 12nm spectral slit width provides the sensitivity required for almost any application.
5.One solid-state silicon detector covers entire wavelength range, eliminating the need to change detectors between different analysis.
6.It is easy to replace the unit of instrument specially the Unit of the Pre-adjusted light source, and make it convenient to maintain.
7.Free adjusting for filter exchange.
8.The grating and toroidal mirrors are selected in optical system.
Technical Parameters
Model
S23A
Wavelength range
340-950nm
Wavelength accuracy
±2.5nm
Wavelength repeatability
≤1nm
Measurement range
0 to 199.0%T, 0 to 1.999A, 0 to 1999C
Photometric accuracy
±1.0%T
Spectral Slit width
12nm
Photometry Accuracy
±2%(T) (tube), ±0.5%(T) (cuvette)
Photometry Repeatability
0.3%τ
Photometry Range
0.0~199.9%(T) -0.3~2.999 A
1~9999 F 0~9999 C
Interface
RS232 serial & parallel interface
Operating voltage
220V±10% or 110V±10%
Standard Package
1. Main unit 1 Set
2. Cuvette holder1 PCs.
3. Glass tube 2 PCs.
4. Power cable 1 PCs.
5. Operation manual 1 PCs.
6. Certificate of quality checking 1 PCs.
7. Fuse (2A) 2 PCs.
8. 1 cm rectangular cell2 PCs.
How to select the test tube
Generally the round test tube is not for optic purpose unless it is pre-checked strictly.
We can select it as follow:
1. Check size. (The size should be f12+0.4x75mm)
2. Check the surface of tube. (It should be no bubbles, no scabs, no thread like things.)
3. Warming instrument according to §4.2.1.1 ~§4.2.1.6 and set the wavelength at 360 nm.
4. Pour some pure water into tube and insert it to the test tube well in sample apartment. Check it just as §4.2.1.7. Then put some mark on the tube opposite the white mark at the instrument.
5. Put the other test tube into instrument one by one and get the readout for everyone and put mark at everyone. We can divide them in many groups. In each group the differential of readout for every tub is less then ±0.02A.
6. Then we can use tubes in same group for blank, sample, and standard solution needn't check the tube every time.
Related Products
UV1700 SeriesUV-VIS Spectrophotometer
UV1900 Dual-beam UV Spectrophotometer
DSH Series Halogen drying method moisture analyzer
Analytical Balance 0-100g/0-110g/0-120g/0-200g/0-210g/0-220g
PHS-3E Precision PH meter
DDS-11A Conductivity Meter 2 uS/cm, 20 uS/cm, 200 uS/cm,2 mS/cm, 20 mS/cm
FACTORY SHOW
Certifications
Our Company