Compact and portable,easy to useSuitable for adult ,pediatric and neonatal patients.
Heart,Lung,Heart and Lung sound modles for Stethoscope.
Large color LCD display of ECG,SpO2 and Pulse rate
Adjustable audible and visual alarms
Real-time monitoring.24 hours storage and review of data
SD card memory, all data can be transferred to a PC
Low power consumption.
Specification
Power Supply : Lithium Battery DC3.6~DC4.2V
Display : 2.4" Color LCD
Stethoscope
Heart:20~230Hz
Lung:100~800Hz
H& L:20~800Hz
Accuracy:± 2 bpm
Heart Rate
Measurement range: 30bpm~300bpm;
Accuracy: ± 2 bpm
Pulse Rate
Measurement range: 30bpm 250bpm;
Accuracy: ± 2 bpm or ± 2%
(Select larger)
SpO2
Measurement range: 35%~100%;
Accuracy: 70~100% (± 2% )
<70% unspecified.Specifications
Real-time detecting
2.4" color LCD
Display of ECG , heart rate,SpO2 ,pulse rate ,pulse waveform
pediatric stethoscope
Pediatric stethoscope Description
CMS-VESD is a kind of multi-functional visual stethoscope. It integrates the functions of auscultation, ECG collection,SpO2 and PR inspection. The product is applicable for family, hospital, private Clinique, community medical treatment.etc.
Pediatric stethoscopeMajor Features
1.Compact and portable,easy to use
2.Display of ECG waveform, heart rate,SpO2 ,pulse rate ,pulse waveform
3.Earphone output and 16 steps volume adjustable
4.Alarm for SpO2 and pulse rate exceeding limits
5.Real-time detecting, TF card data record and review
6.Real-time clock
7.Recorded data can be transferred to a PC
8.PC analysis software
9.Low power consumption
Pediatric stethoscopeMain performance
1.Stethoscope:(electronic sensor ,three Stethoscope modes),
Heart:20~230Hz,Lung:100~800Hz,H&L:20~800Hz
2.Heart Rate measuring range: 30bpm~300bpm ,Accuracy: ±2 bpm or ±2%
(select larger)
3.SpO2 measuring range: 0%~100% (the resolution is 1%),Accuracy: 70%
~100% :±2% ,below 70% unspecified
4.Pulse Rate measuring range: 30bpm~250bpm,Accuracy: ±2 bpm or ±2%
(select larger)
5.Resistance to surrounding light: The deviation between the value measured
in the condition of man-made light and indoor natural light and that of
darkroom is less than ±1%.
6.Measurement Performance in Weak Filling Condition: SpO2 and pulse rate
can be shown orrectly when pulse-filling ratio is 0.4%. SpO2 error is ± 4%,
pulse rate error is ±2 bpm or ±2% (select larger).
7.Display : 2.4" color LCD
8.Power consumption:≤120mA
9.Voltage:DC 3.6 ~ 4.2V
10.Power Supply: 3.7V Lithium Battery
11.Battery working hour:It can last more than 7 hours when the power is full.
12.Safety Type: Internally powered equipment,B Type
Pediatric stethoscopeAccessories
An User Manual
An Earphone
A Power adapter
A data line
An oximeter probe (optional, BF applied part )
A CD(PC software)
Pediatric stethoscopePhysical Identity
Dimension: 110mm(L)x60mm(W)x14mm(H)
Weight: 100g