Supplier Homepage Health & Beauty & Medical Health & Medical General Assay & Diagnostic Apparatuses Finger pulse oximeter oximeter finger with fingertip JPD-500A CE FDA marked

Finger pulse oximeter oximeter finger with fingertip JPD-500A CE FDA marked

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $15.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: Jumper
Place of Origin: China
Brand Name: Jumper
Model Number: JPD-500A

Finger pulse oximeter,oximeter finger with fingertip JPD-500A CE & FDA marked
Packaging & Delivery
Packaging Details:Unit weight:0.09kg,size:8.3*7.7*5.0cm
Carton weight:10kg,size: 42*39*28cm
100pcs into one cartonDelivery Detail:Shipped in 5 days after payment
Product DescriptionProduct Description
Jumper JPD-500A fingertip pulse oximeter
Feathers:
0.Smal,light,convenient
1.SpO2,PR and Perfusion Index value display
2.Pulse rate value display, bar graph display
3.Low-voltage indication, Pulse sound, Alarm function
4.Auto shut off without signal after 16s
Specification:
1. OLED display, brightness adjustable.
2.SpO2 Measuring Range (0%~100%, (the resolution is 1%).
3. Accuracy 70%~100%:±1% ,Below 70% unspecified
4.PR Measuring Range 25bpm~250bpm, (the resolution is 1bpm)
5.Accuracy ±1bpm or ±1% (select larger)
6.Measurement Performance in Weak Filling Condition
7.SpO2 and pulse rate can be shown correctly when pulse resistance to surrounding light
8.Power Consumption less than 25mA
9.Voltage DC 2.6V~3.6V
10.Power Supply 1.5V (AAA size) alkaline batteries x 2
Precautions for use
1 Do not use the pulse oximeter in an MRI or CT environment
2 Do not use the pulse oximeter in situations where alarms are required. The device has no alarms.
3 Explosion hazard: Do not use the pulse oximeter in an explosive atmosphere.
4 The pulse oximeter is intended only as an adjunct in user assessment. It must be used in conjunction with other methods of assessing clinical signs and symptoms.
5 Check the pulse oximeter sensor application site frequently to determine the positioning of the sensor and circulation and skin sensitivity of the user.
6 Do not stretch the adhesive tape while applying the pulse oximeter sensor. This may cause inaccurate readings or skin blisters.
7 Before use, read the manual carefully.
8 The device is not for continuous monitoring.
9 Prolonged use or the user’s condition may require changing the sensor site periodically. Change sensor site and check skin integrity, circulatory status, and correct alignment at least every 4 hours.
10 Inaccurate measurements may be caused by autoclaving, ethylene oxide sterilizing, or immersing the sensors in liquid.
11 Significant levels of dysfunctional hemoglobins (such as carbonxy- hemoglobin or methemoglobin) may cause inaccurate readings.
12 Intravascular dyes such as indocyanine green or methylene blue.
13 SPO2 measurements may be adversely affected in the presence of high ambient light. Shield the sensor area (with a surgical towel, or direct sunlight, for example) if necessary.
14 Excessive user movement may cause inaccurate readings.
15 Venous pulsations may cause inaccurate readings.
16 High-frequency electrosurgical interference may cause inaccurate readings.
17 Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line.
18 The user has hypotension, severe vasoconstriction, severe anemia, or hypothermia.
19 The user is in cardiac arrest or is in shock.
20 Fingernail polish or false fingernails may cause inaccurate SPO2 readings.
Follow local ordinances and recycling instructions regarding disposal or recycling of the device and device components, including batteries.
Packing & DeliveryPacking & Delivery
Our CompanyOur Company
Shenzhen Jumper Medical equilpment co.,Ltd was established in 1998, integreted by USA jumper coperation and Shenzhen jumper trading company,Jumper is a joint venture enterprise.Self-R&D team from aboard experts leading China highest university Peking university,Qinhua, Shanghai Jiao Tong University mater and doctors. with ISO 9001:2000 and ISO13485:2003 quality management systems approved,we very strictly control our products quality,provide our clients the highest quality and high stability as well.
And also with CE&FAD certificated approved.We are the one of largest fetel doppler manufacturers in the world.mainly do:
fetal doppler,fetal monitor,fetal&maternal monitor, patient monitor,pulse oximeter,blood pressure monitor, thermometer,etc.

Send your message to this supplier

*From:
To:
Shenzhen Jumper Medical Equipment Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now