Specifications:
Human chorionic gonadotropin (HCG) is a hormone, produced by the developing placenta shortly after the conception and secreted into the urine. One Step hCG Pregnancy Urine Test is a rapid pregnancy test. It adopts double antibody sandwich method detects the presence of human chorionic gonadotropin (hCG), which appears in urine very early during pregnancy.
Characteristic:
*Early detection of pregnancy as early as 7 days after the fertilized egg implantation.
*Simple to use
*A variety of design specifications suitable for self-testing use and for professional use
*Results in 3 to 5 minutes
*Store in room temperature
*24 months shelf life
Performance:
*Sensitivity:25 mIU/ml, 20 mIU/ml, 15 mIU/ml,10 mIU/ml
*Specificity:No cross-reactivity with 300 mIU/ml hLH, 300 mIU/ml hFSH, and 1000 mIU/L hTSH
Read the entire procedure carefully before performing any tests.
Allow test strip and urine specimen to equilibrate to room temperature (20-30℃ or 68-86℉) prior to testing.
1. Remove the test strip from the sealed pouch.
2. Holding the strip vertically, carefully dip it into the specimen with the arrow end pointing towards the urine.
NOTE: Do not immerse the strip past the Max Line.
3. Remove the strip after 10 seconds and lay the strip flat on a clean, dry, non-absorbent surface, and then begin timing.
4. Wait for colored lines to appear. Interpret the test results at 3-5 minutes.
NOTE:Do not read results after 5 minutes.
Positive: Two distinct red lines will appear,one in the test region (T) and another in the control region (C). You can assume that you are pregnant.
Negative:only one red line appears in the control region (C). No apparent line in the test region (T). You can assume that you are not pregnant.
Invalid: The result is invalid if no red line appears in the control region (C), even if a line appears in the test region (T).In any event, repeat the test. If the problem persists, discontinue using the lot immediately and contact your local distributor.
NOTE: Clear background in the Result Region can be seen as a basis for effective testing. If the test line is weak, it is recommended that the test be repeated with the first morning specimen obtained 48-72 hours later. No matter how the test results, it is recommended to consult your physician.
Precution
1.For in vitro diagnostic use only
2.Do not use test components beyond their expiration dates
3.Dispose of all potentially contaminated test components in a biohazard container
Our Services: