Ventilas SE-01 Ventilator

Get Latest Price
Min. Order / Reference FOB Price
1 US $15.00/
Local Area: Turkey
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Portable ventilator.All settings and alarm data of the device is kept in its memory,the operation values set are saved in its memory even though the device is turned off or the internal battery is off.
1- PEEP between 0-20 mb can be applied on the device using a PEEP valve.
2- The device has the feature of doing volume and pressure controlled ventilation.
3- the device can work with 12 vdc chargeable internal battery and with 185-240 volt 50/60 hz city electricity(+%10) for 1-1.5 hrs.
4- the device charges its internal battery as long as it is connected to the city electricity and the situation of internal battery can be followed from the front panel.
5- when the electricity goes off the device starts the internal battery automatically and gives warning both with light and sound.
6- when the device operates with the acumulator,it announces the internal battery levels %75,%50,%25 with light and sound alarms.
7- the device operates by using the air of the atmosphere it is in without needing preesured air or pressured oxygen.
8- the device has the capability of operating with automatic lighter cable,also same entry can be used as external battery entry,these voltage entries are protected against opposite connection.
9- oxygen entry to the device is carried out by the flow metre exits which exist in oxygen resources.
10- all settings and alarm data of the device is kept in its memory,the operation values set are saved in its memory even though the device is turned off and on or the internal battery is off.
11- the device is micro-operator controlled and all settings are done with touch-sensitive keys.
12- the whole data is displayed on lcd screen.
13- detailed explaination about all the menu data and alarms are displayed on lcd screen.
14- the device shows the total operation time and this data is never erased; also there is a second operation timer which starts each time the device starts operating.
15- the alarm data on the front panel and lcd screen of the device directs the user and warns both with light and sound.
16- the following alarms exist within the device and in addition to these the lcd menu related to these includes informing data too.
a)low pressure
b)high pressure
c)apnea alarm 15-40 seconds
d)pressure security alarm
e)bellow system alarm
f)internal battery
g)network electricity error(power alarm)
h)maximum breath number alarm 15-70
17- the device can be set between the following parameters,it displays the beginning of parameter as min and the end as max.
a-pcv pressure level 10-40 mbar
b-breath flow rate 0.30-1.50 lt/second
c-plateau time 0.0-2.0 seconds
d-minute volume 4-30 litres
e-frequency 8-40breaths/minute
f)SIMV frequency 8-40 breaths/minute
g)supporting pressure level 0.5-40 mbar
18- the values of the device in SIMV ventilation mode operates according to the values set in its back up as pcv or cv. spontaneous ventilation of the patient is pressure supported.
a-back-up mode can be chosen as PCV or CV.
b-tidal volume 200-1200 ml
c-I:E.1:1-3 min/sec
d-low pressure alarm level 2-40 mbar and 100 ml-1000 ml
e-high pressure alarm level 20-60 mbar
f-trigger level =(-1)-(-3) mbar
19- The device has a lightened bar graph displaying the patient pressure betweeen 20-80 mbar which enables the inspiration,expiration,low pressure,high pressure,trigger sensitivity to be followed. also,the set and real alarm values may be seen from the lcd screen when they are reset.
20- the device has the following ventilation modes;
a-VC(mandatory,controlled ventilation)
b-VAC(assist controlled ventilation)
c-PSV(pressure supported ventilation)
e-SIMV(synchronized intermediate mandatory ventilation)
21- when the device turns off with any reason,it has a mechanism that enables the patient´s spontaneous ventilation.
22- The air entry of the atmosphere into the device is carried out through a bacteriae filter which has the property of being observed and easily changed by the patient.
23- The necessary apparatus with the device for one set and the patient circuit are the following;
a-portable ventilator(artificial ventilating device)
b-wheeled carrying stand
c-mobile hose holder and its apparatus
d-electronic controlled humidifier and chamber
e-reusable 120cm and 40 cm patient circuit and its valve
f-oxygen circuit and balloon,bacteriae filter
g-12 VDC vehicle lighter cable
h-Turkish operation manual.
24- The device can be used as volume controlled, starting from 7.5 kg patients to the adults of all ages both for portable and clinical purposes.
25- The device weighs 8 kgs.
26- The device can be applied with mask as invasive or non-invasive.
27- The sizes are H:160 W:300 L:300 mm
28- Tere are menu options in english and in turkish