2018 KL compressed air dryer after cooler
Ⅰ. Air Cooled After Cooler
A.Production Overview
KLF series after cooler is installed after screw or piston air compressor, it can cool the incoming high temperature & pressure compressed air to the a certain degree( below 45°C ), also can condense the most of water vapour into liquid which will be discharged out. It improves the working conditions of down stream equipments, avoiding the problems caused by water suspension and condensation and prolong their service life.
B,Work principle
When the high temperature & pressure air comes from compressor entering into the after cooler through inlet port, it will exchange the heat with cold air coming from after cooler, then cooled air will enter into other devices.
C,Rated Working Conditions
Air inlet pressure 0.7MPa,air inlet temperature 80°C,air outlet temperature 45°C,ambient temperature 35°C,pressure drop of compressed air 0.015MPa.1N
2N
3N
6N
10N
12N
15N
20N
25N
M3/min
1.6
2.6
3.8
7
11.5
13.5
17
23
27
Voltage
1 PH 220V 50HZ
3PH 380V 50HZ
L (mm)
600
650
650
800
1180
1180
1500
1500
1670
W (mm)
200
200
250
270
270
270
340
340
340
H (mm)
700
700
700
800
850
950
975
1020
1030
Power (W)
50
90
90
120
300
300
360
360
500
Pipe
1”
1”
1”
11/2
2”
2”
DN65
DN65
DN65