Business Type:
Trading Company
Business Range:
Medical Stents, Esophageal Stent System, Biliary Stent System, Bronchial and Tracheal Stent System, Intestinal Canal Stent System
Establishment:
2013
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Mid East, North America, South America
OEM/ODM Service
Sample Available

Our company has more than ten years experience in manufacturing and trading denim fabrics, twill fabrics, yarn dyed fabrics and single jersey fabrics. With advanced technical equipments, 6 sets of siz...

1
    YRS
General Supplier

Nitinol metallic partially covered tracheal stent

Get Latest Price
Min. Order / Reference FOB Price
10 Set US $120.00/ Set
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Brand: FLEXTENTtracheal stent
Properties: Implant Materials & Artificial Organs
Type: Stent
Brand Name: FLEXTENTtracheal stent

Product Description
Nitinol metallic partially covered tracheal stent
Tracheal and Bronchial stent
Indications for use
Complex stricture at the lower segment of trachea, carina and bronchus.
Specification table
Delivery device
Stent structure
1 --vertical cylinder structure; 2--proximal cup, distal ball 3--two tulip ends; 4--two cup ends; 5-- proximal ball, distal ball for OTW introducer;6----J shape;7—Y shape; 8-- proximal ball, distal ball for TTS introducer ;9--proximal cup, distal umbrella 0--others
Stent deployment procedure
a) Under the fluoroscopy guidance, position the delivery device exactly to the center of the target stricture or tumor.
b) Loosen the safety lock by turning it counterclockwise when the delivery device is correctly positioned at the stricture.
c) Immobilize the inner shaft by holding firmly the posterior handle in one hand, and gently pull the outer sheath backward. Do not push the inner shaft when you deploy the stent. The inner shaft should be held securely and not be allowed to move. Pushing the inner shaft will cause misalignment of the stent and possible damage to the oesophagus.
d) After the stent is fully deployed, withdraw the delivery device and guide wire carefully.
e) Examine the stent fluoroscopically to confirm expansion. If excessive resistance is felt during the removal, wait 3-5 minutes to allow further stent expansion.
Advantage
Our advantage is that we can provide medical training services, doctors clinical operations guidance and other services.
Packaging & Shipping
Package details
Sterilized single-packageSingle packed with color box :71*29*3 cm 10 sets into a carton :71*29*33 cm


Company Information
Our factory workshop
Our products

Certifications
contact information
Export Sales : Lyon
Phone Number: +86 18661150577
Tel: +86 519-89815768
Skype:joyce_pride
Contact us freely for more details and information if you are interested in our products!

Send your message to this supplier

*From:
To:
Pride Imp & Exp Co., Ltd.
*Message:

Enter between 10 to 1,000 characters.

*Email code:
This is not what you are looking for? Post a Sourcing Request Now